Select this when raising the output voltage to near the input voltage, or when the input voltage
changes.
B712
:
ACR Feed Forward Selection
=0: Disable =1: Enable
The voltage fluctuation caused by the leakage inductance is feed forward controlled. The current
regulator (ACR) response speed will be increased.
GROUP – 8: M FLUCTUATION COMPENSATION TABLE
B801 ~ B808
:
Table Reference Speed 1 ~ 8
This is the reference speed for changing the compensation amount according to the operation speed.
These parameters value will automatically set with Maximum Frequency. Default value as per
50/60Hz.
B809 ~ B816
:
Lm Fluctuation Compensation Coefficient 1 ~ 8
This compensates the exciting inductance fluctuation according to the B801 ~ B808 reference speed.
Set the compensation table so that the output voltage is constant during no-load operation through the
entire operation range. This is adjusted with the automatic tuning selection (B201) mode 4 (Extended
rotational) is executed.
Summary of Contents for Axpert-Eazy AMT-011-4
Page 2: ...Amtech ii...
Page 19: ...Axpert Eazy AC Variable Frequency Drive 2 11 2 400V Series AMT 200 4 AMT 250 4...
Page 22: ...Amtech 2 14 2 This Page is intentionally left blank...
Page 37: ...Axpert Eazy AC Variable Frequency Drive 4 9 4...
Page 38: ...Amtech 4 10 4 This page is intentionally left blank...
Page 46: ...Amtech 5 8 5 This page is intentionally left blank...
Page 216: ...Amtech 13 6 13 This page is intentionally left blank...
Page 221: ...Axpert Eazy AC Variable Frequency Drive A 5 13 A Outline Dimensions...
Page 239: ...Notes...
Page 240: ...Notes...
Page 241: ......
Page 242: ...AMTECH...