4
Check
- Did the motor run?
- Is the run direction correct? Check the wiring and operation if abnormal.
- Is the rotation smooth?
Select “REVERSE” direction in ‘A305: Motor Direction’ and Press “RUN” and confirm that the motor
runs normal in reverse direction.
(Note)
Do not carry out this step if a load, which cannot be run in reverse, is connected.
Press the “STOP” key and stop the motor. Now, again set the “FORWARD” direction in ‘A305: Motor
Direction’ and increase the frequency to 50Hz.This completes the test operation with the operation
panel.
After this, carry out the parameter settings and adjust the load operation to match the user's
application.
Manual adjustment when torque accuracy is required (IM vector control mode)
In applications, which require high actual output torque accuracy in respect to the torque command
(within
±
10% of the rated output torque), the manual adjustments of Group-6 and Group-7 parameters
may be required.
The Speed control system of IM vector control is configured of blocks as shown below.
Summary of Contents for Axpert-Eazy AMT-011-4
Page 2: ...Amtech ii...
Page 19: ...Axpert Eazy AC Variable Frequency Drive 2 11 2 400V Series AMT 200 4 AMT 250 4...
Page 22: ...Amtech 2 14 2 This Page is intentionally left blank...
Page 37: ...Axpert Eazy AC Variable Frequency Drive 4 9 4...
Page 38: ...Amtech 4 10 4 This page is intentionally left blank...
Page 46: ...Amtech 5 8 5 This page is intentionally left blank...
Page 216: ...Amtech 13 6 13 This page is intentionally left blank...
Page 221: ...Axpert Eazy AC Variable Frequency Drive A 5 13 A Outline Dimensions...
Page 239: ...Notes...
Page 240: ...Notes...
Page 241: ......
Page 242: ...AMTECH...