V-48
13. CLEARING EMERGENCY STOP
CONDITION
When one of the EMERGENCY STOP buttons is pressed, the ram and
the hydraulic pump motor immediately stop, and the EMERGENCY
lamp comes on. Clear the emergency stop condition as described
below.
1
Pull the pressed EMERGENCY STOP button.
2
If the multiple opening limit of the ram is set, turn up the multiple
opening limit setting lever to clear the multiple opening limit.
3
Press the DOWN button to open the ram to the maximum opening
limit and extinguish EMERGENCY LAMP.
4
Press the HYD. ON button to start the hydraulic pump motor.