V-47
Symptom
Cause
Remedy
Pressure adjusting knob is not
tightened.
Turn it fully clockwise (+).
Rising speed change position is not
properly set.
Set it again as described in “10-1.
Setting rising speed change position”
in this Part.
Oil level in hydraulic oil tank is low.
Add oil as described in “2.
Maintaining hydraulic system” in Part
VI.
Hydraulic pump is faulty.
Contact AMADA.
Filters in hydraulic oil tank are
clogged.
Clean or change them as described
in “2. Maintaining hydraulic system”
in Part VI.
Specified
pressure is not
delivered.
Seal in cylinder is worn.
Contact AMADA.
Multiple opening limit is not properly
set.
Set it again as described in “10-2.
Setting multiple opening limit” in this
Part.
Multiple opening
limit of ram
cannot be set.
Multiple opening limit setting lever is
faulty.
Contact AMADA.
Multiple closing
limit of ram
cannot be set.
Handwheel lock knob was
overloosened so that multiple closing
limit setting handwheel became
faulty.
1 Remove handwheel lock knob.
2 Expand internal pin with scriber or
other sharp-pointed tool.
3 Reinstall handwheel lock knob as
shown below. If you are unable
to remedy trouble, contact
AMADA.
NORMAL
FAULTY
PIN
LOCK KNOB
LOCK KNOB OVERLOOSENED
SCRIBER
EXPAND INTERNAL PIN WITH SCRIBER
OR OTHER SHARP-POINTED TOOL
Summary of Contents for RG35S-100
Page 1: ...RG25 125 E02 200510 PRESS BRAKE ZII RG35S 100 OPERATOR S MANUAL...
Page 6: ...vi...
Page 7: ...I 1 Part I Safety 1 Safety rules I 2 2 DANGER and WARNING plates I 10...
Page 18: ...I 12...
Page 22: ...II 4...
Page 100: ...VI 8 4 HYDRAULIC CIRCUIT DIAGRAMS 4 1 RG35S...
Page 102: ...VI 10 4 2 RG50 RG80 and RG100...
Page 104: ...VI 12...
Page 106: ...VI 14...
Page 109: ......
Page 110: ...AMADA COMPANY LTD 200 Ishida Isehara Kanagawa JAPAN Printed on recycled paper...