1-1. Environmental conditions
•
Keep the machine at least 10 m {33 ft} away from a welder or any
other equipment that may produce electrical noise and magnetic
fields.
•
Where the ambient temperature is not higher than 5
°
C {41 °F}, keep
the machine and hydraulic pump motor energized during the day's
work.
•
The higher the humidity in the place where the machine is installed,
the lower the insulation performance of its electric parts becomes.
This results in the premature degradation of the electric parts. Do
not install the machine in such a humid place.
•
Install the machine in a place where it is not subjected to dust, dirt,
and organic or corrosive gases.
1-2. Input power source
Power requirement:
200/230/380/400/460 VAC±10% (transformer tap
and motor wiring is required), 3 phases, 50/60 Hz±1 Hz
NOTICE
O
Supply the machine from a power source independent of a welder or any
other equipment that may produce line voltage variations. Otherwise the
machine may misoperate.