90
ML-3030AS/3015AS
4 . Setting the Laser Light Output Schedule
2
Setting ON/OFF for the Modulation Function
(1) Press the "MODU" button to display the MODULATION screen.
(2) Move the cursor to "MODU" and press the ON or OFF key to set whether the
modulation function is valid or not.
At ON, the modulation function set on the MODULATION screen is enabled.
When this function is not used, set OFF.
⇒
For the setting method of the modulation function, refer to "Setting the Modulated
waveform" on page 97.
(3) Press the "X" button to display the SCHEDULE screen.
3
Setting ON/OFF for the Output Schedules for Seam Welding
(1) Press the "SEAM" button to display the SEAM screen.
(2) Press the "SEAM" setting button and set the seam welding output schedule to
ON/OFF.
At ON, the fade function for seam welding set on the SEAM screen is enabled.
When this function is not used, set OFF.
⇒
For the setting method of the output schedules for seam welding, refer to "Setting
the Output schedules for Seam Welding" on page 93.
⇒
When the laser light output count is set to 9999 by using the "SHOT" setting but-
ton, a laser light is continuously output until the laser stop signal is input and the
fade-in/out function becomes disabled.
(3) Press the "X" button to display the SCHEDULE screen.