Specifications
181
ML-3030AS/3015AS
Peak power limitation by ambient temperature and average power (duty cycle)
There are limitations of peak power by average power (duty cycle) at ambient tem-
perature above 21°C. Refer to the graph below to set the peak power so that the
peak power does not exceed the limit.
ML-3030AS
Ex.) A limitations of peak power with 300 W of average power is 2.65 kW (REPEAT
mode) at ambient temperature 35°C. In this case, configure the setting of the
pulse waveform to 2.65 kW or less. (Do not include the area above 2.65 kW.)
REPEAT mode
CW mode
0
50
100
150
200
250
300
350
0
5
10
15
20
25
30
35
40
Ambient temperature (°C)
0
50
100
150
200
250
300
350
0
5
10
15
20
25
30
35
40
Ambient temperature (°C)
Range that the peak power
is limited to 2.65 kW or less
Range that the peak power
is limited to 2.60 kW or less
Range that the peak power
is limited to 265 W or less
Range that the peak power
is limited to 260 W or less
Average power (W)
Average power (W)