When Using a Contact Signal
10k
10k
TLP180
TLP197G
24V
EXT 0V
RY
EXT. I/O(1): 2 to 6, 25
EXT. I/O(2): 16, 17, 22,
27 to 34
EXT. I/O(1): 11 to 17, 20,
22, 23
EXT. I/O(2): 3, 4, 9
EXT. I/O(1): 21
EXT. I/O(2): 14
EXT. I/O(1): 1
EXT. I/O(1): 9
EXT. I/O(1): 19
EXT. I/O(1): 10
EXT. I/O(2): 35
4.7k
4.7k
TLP180
EXT +24V
+24V output
0V output
*1
*1
Normally closed
for
Laser Stop
Load
Inside of the laser
Input circuit
Output circuit
Output COM
Input COM
Emergency
stop