168
ML-3030AS/3015AS
2 . Maintenance of the Power Supply Section
2 . Maintenance of the Power Supply Section
Cleaning the Air Filter
An air filter on the front face of the main unit is provided at the air inlet to the power
supply section. Perform cleaning every month.
<Note>
Not performing cleaning of the air filters decreases the cooling capacity and af
-
fects the service life of parts such as LD . To give normal performance of the laser
welder, perform cleaning periodically .
Operating Procedure
(1) Open the front door.
(2)
Remove two filter fixing screws by manually turning them.
(3)
Take out the air filter and wash it in tap water. Then, dry the air filter completely.
⇒
When the air filter is very dirty, use a neutral cleaner.
(4)
Install the air filter and tighten the bezel with the filter fixing screws.
Filter fixing screw
(2 positions)