188
ML-3030AS/3015AS
Timing Chart
Repeated operation (EXTERNAL CONTROL)
The following diagram shows the lapse of time in the case where a signal is sent from
the PLC and schedule signal input, BEAM1 is selected, and then laser light is output
from input unit 1.
*1 1s max.
LD output preparation time
*2 150ms or more Shutter operation time
*3
Time required for the end signal to be output after a laser output
*4
Time required for outputting a signal to indicate whether the laser
energy is within the set upper limit value (HIGH) and lower limit value
(LOW) of monitor output
In *3 and *4, the output time is 20 ms but can be changed to 30 or 40 ms on the CONFIG screen.
LD ON Output
Schedule 1 Input *
Schedule 2 Input *
Schedule 4 Input *
Schedule 8 Input *
Schedule 16 Input *
Schedule 32 Input *
Schedule 64 Input *
Schedule 128 Input *
Ready Output
Beam Select 1 Input *
(except ML-30□□AS-110)
Laser Start Input *
(Laser light)
Laser Stop Input *
End Output
Monitor Normal/
Trouble Output
(*: Operation on the user side)
Laser beam is output repeatedly
according to Schedule 7
The laser repetition stops when
Laser Stop signal is input
Continuous output from input unit 1
*4
1ms or more
150ms or more *2
1s max . *1
The time set on the
CONFIG screen or more
The time set on the CONFIG screen *3
Summary of Contents for ML-3015AS
Page 21: ...Introduction Part...
Page 22: ......
Page 30: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 52: ......
Page 53: ...Operating Part...
Page 54: ......
Page 163: ...Maintenance Part...
Page 164: ......
Page 175: ...Appendixes...
Page 176: ......