1 . Error Display and How to Take a Measure
171
ML-3030AS/3015AS
Chapter 2 Inspection and Measure T
o Be T
aken at Occurrence of an Error
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
No .
Contents of error
LD
Alarm
output
Measures
027
AC POWER DOWN(PDI)
OFF
ON
A temporary blackout of AC power supply was de-
tected.
Check the power supply environment.
028
INTERLOCK SIGNAL ERROR
OFF
ON
An error of unknown cause has occurred with the
interlock.
Consult us.
029
SHUTTER BOARD 5V ERROR
OFF
ON
A 5V DC power error has occurred with the shutter
drive board.
Consult us.
035
LASER POWER OUT OF RANGE
-
-
The monitor value of laser energy is out of the
range of "HIGH" and "LOW" set on the MONITOR
screen. → P.70, P.103, P.105, and P.123
Check "HIGH" and "LOW" settings. If monitored
value is abnormal, consult us.
036
LASER CONTROL PARAMETER
ERROR
OFF
ON
A set value of laser energy (PEAK POWER, output
time, REPEAT) exceeds the capacity.
The error message is displayed when inputting the
set value. The set value is reset to the value before
the change.
037
VIBRATION DETECTED
OFF
ON
Shock and vibration has been detected.
Check around any other trouble. After checking that
nothing is damaged, press the RESET button.
050
to
054
POWER FEEDBACK OVERFLOW
to
POWER FEEDBACK4 OVERFLOW
OFF
ON
The power set by the power feedback cannot be
output.
When interlock is operated during laser output,
this error may occur. If E050 to E054 occurs alone,
consult us.
060
POWER FPGA ERROR1
OFF
ON
An error has occurred with the controller unit.
Consult us.
061
POWER FPGA CALC. ERROR
OFF
ON
An error has occurred with the controller unit.
Consult us.
062
DIV BY 0 ERROR
OFF
ON
An error has occurred with the controller unit.
Consult us.
067
INTERNAL RS-232C ERROR
OFF
ON
The communication line in the main unit is abnor-
mal.
If there is any noise generation source nearby,
separate it as far as possible or take a preventive
measure for occurrence of noise.
068
INTERNAL RS-232C TIMEOUT
OFF
ON
The communication line in the main unit is abnor-
mal.
If there is any noise generation source nearby,
separate it as far as possible or take a preventive
measure for occurrence of noise.
069
PANEL 485COMM TIMEOUT
OFF
ON
The communication line in the main unit is abnor-
mal.
If there is any noise generation source nearby,
separate it as far as possible or take a preventive
measure for occurrence of noise.
Summary of Contents for ML-3015AS
Page 21: ...Introduction Part...
Page 22: ......
Page 30: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 52: ......
Page 53: ...Operating Part...
Page 54: ......
Page 163: ...Maintenance Part...
Page 164: ......
Page 175: ...Appendixes...
Page 176: ......