4 . Setting the Laser Light Output Schedule
89
ML-3030AS/3015AS
Chapter 2 V
arious Settings
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
(5) Press the laser output time "TIME [ms]" and laser output value "POWER [%]"
setting buttons of "FLASH1" to "FLASH3."
Enter each value by using the numeric keypad and then press the ENT key.
⇒
The laser output time is set in the range of 0.0 to 50.0 ms. Regarding the laser
output value, the ratio (%) based on the case where the set laser output peak
value is 100% is set.
<Notes>
- Set the laser output time so as to result in the following value .
0.2 ms ≤ FLASH3 ≤ 50.0 ms
- When the laser output value (%) is set to 0 .1% or more, the laser output peak val-
ue (PEAK POWER x laser output value POWER [%]) cannot be set falling below
the minimum value of laser output (ML-3030AS: 0 .5 kW, ML-3015AS: 0 .25 kW) .
(6) To insert the non-laser output time between "FLASH1" and "FLASH2", press the
COOL button to set the output stop time (ms) in "COOL1."
(7) To insert the non-laser output time between "FLASH2" and "FLASH3", press the
COOL button to set the output stop time (ms) in "COOL2."
<Note>
Set the laser output time and the non-laser output time so as to result in the fol-
lowing value .
COOL1 + COOL2 + FLASH3 ≤ 50.0 ms
(8) Press the "
SLOPE" setting button.
Enter the time "TIME [ms]" required for laser light to up-slope (get gradually
stronger) in FLASH1 by using the numeric keypad, and then press the ENT key.
<Note>
The output time of FLASH1 includes the time of "
SLOPE ."
Set "
SLOPE" so as to result in the following value .
SLOPE ≤ FLASH1
(9) Press the "
SLOPE" setting button.
Enter the time "TIME [ms]" required for laser light to down-slope (get gradually
weaker) in the last FLASH by using the numeric keypad, and then press the ENT
key.
<Note>
The output time of the last FLASH includes the time of "
SLOPE ."
Set "
SLOPE" so as to result in the following value .
SLOPE
≤
FLASH1, FLASH2, FLASH3
(10) To output laser light several times for one second, press the "REPEAT" setting
button and then set the laser light output count for one second in the range of 1
to 1000 pps (pulse per second) by using the numeric keypad.
(11) To output laser light repeatedly, press the "SHOT" setting button and set the laser
light output count in the range of 1 to 9999 by using the numeric keypad.
⇒
When 1 is set, a single output is performed.
Summary of Contents for ML-3015AS
Page 21: ...Introduction Part...
Page 22: ......
Page 30: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 52: ......
Page 53: ...Operating Part...
Page 54: ......
Page 163: ...Maintenance Part...
Page 164: ......
Page 175: ...Appendixes...
Page 176: ......