3 . Changing the Equipment Settings
81
ML-3030AS/3015AS
Chapter 2 V
arious Settings
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
USER SETTING
How to see the displayed items
: Settable item
Ext .I/O "MONITOR TROU-
BLE" OUTPUT TIMING
(CW)
Sets the output timing of the monitor upper/lower limit check error
in the CW waveform.
SCH. OUTPUT END: Output when output ends (default)
MON. TRB. DETECT: Output when the error occurs (The normal
output signal is turned ON during output until the error occurs.)
OUTPUT Ext .I/O "TROU-
BLE" by REM .I/L ERROR
Sets whether to output the error by the external input/output when
error No.022/EXTERNAL INTERLOCK OPENED occurs.
EXEC: Output (default)
NONE: Not output
AUTO LD POWER CHECK
Not used.
PEAK-POWER
SYNCHRONIZE
Sets whether to use the peak power synchronize setting. Func-
tions and displays related to the peak power synchronize setting
are valid only when this is set to USE.
NONE: Not use (default)
USE: Use
X
Returns to the INITIALIZE screen.