1 . Error Display and How to Take a Measure
173
ML-3030AS/3015AS
Chapter 2 Inspection and Measure T
o Be T
aken at Occurrence of an Error
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
No .
Contents of error
LD
Alarm
output
Measures
111
OSCILLATOR1 LEAK CURRENT HIGH ERROR OFF
ON
An excessive leak current error has been detected.
Consult us.
112
OSCILLATOR1 CRITICAL ERROR
OFF
ON
A serious failure has occurred with the oscillator.
Consult us.
113
OSCILLATOR1 AVERAGE POWER HIGH ERROR OFF
ON
An excessive average power error has been de-
tected.
Consult us.
114
OSCILLATOR1 FIBER INTERLOCK ERROR
OFF
ON
An optical fiber is wrongly connected or may be
broken.
Check that the fiber is normally connected. If the
trouble will continue even after the above mea-
sures, consult us.
169
ISOLATOR DUMPER TEMP ERROR OFF
ON
Abnormal temperature of the isolator dumper.
After waiting for several minutes, press the TROU-
BLE RESET button.
170
171
SAFETY SHUTTER 1 OPEN
TROUBLE
SAFETY SHUTTER 2 OPEN
TROUBLE
OFF
ON
The safety shutter unit fault.
Consult us.
174
175
SAFETY SHUTTER 1 CLOSE
TROUBLE
SAFETY SHUTTER 2 CLOSE
TROUBLE
OFF
ON
The safety shutter unit fault.
Consult us.
178
179
SAFETY SHUTTER 1 TEMP ERROR
SAFETY SHUTTER 2 TEMP ERROR OFF
ON
Abnormal temperature of the safety shutter.
After waiting for several minutes, press the TROU-
BLE RESET button.
182
BRANCH MIRROR TEMP ERROR
OFF
ON
Abnormal temperature of the branch unit.
After waiting for several minutes, press the TROU-
BLE RESET button.
185
BRANCH MIRROR 1 OPEN TROUBLE
OFF
ON
An error has occurred with the timesharing unit.
Consult us.
188
BRANCH MIRROR 1 CLOSE TROUBLE
OFF
ON
An error has occurred with the timesharing unit.
Consult us.
191
SHUTTER CONTROL ERROR
OFF
ON
A control error of the shutter unit.
Make sure that the laser start signal is not input be-
fore a shutter is open.
193
194
FIBER SENSOR 1 TROUBLE
FIBER SENSOR 2 TROUBLE
OFF
ON
An optical fiber may be broken; or end face, dam
-
aged.
Check all the optical fibers for breakage. If the end
face is broken, consult us.
Summary of Contents for ML-3015AS
Page 21: ...Introduction Part...
Page 22: ......
Page 30: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 52: ......
Page 53: ...Operating Part...
Page 54: ......
Page 163: ...Maintenance Part...
Page 164: ......
Page 175: ...Appendixes...
Page 176: ......