3 . Initial Settings
Perform initial settings to control laser welding by external communication
(RS-485 CONTROL) . Set communication schedules and equipment No . on the
control panel .
The communication schedules for data transfer are as follows.
Data transfer system
Conforming to RS-485, asynchronous, full duplex
Transfer rate
9600, 19200, 38400, 57600, 115200 bps
Data type
Start bit
1
Data bit
8 or 7
Stop bit
2 or 1
Parity bit
Even/odd/none
Character code
ASCII
⇒
Set the transfer rate, data type, and equipment No. by displaying the RS-485
COMMUNICATION SETUP from the CONFIG screen by the control panel of
each equipment that is connected to the personal computer, etc.
Setting Communication Schedules and Equipment No .
Set the communication schedules and equipment No . by displaying the RS-485
COMMUNICATION SETUP from the CONFIG screen by the control panel of the
equipment .
1
Displaying the CONFIG Screen
(1) Press the "CONFIG" button to display the CONFIG screen.
(2) Press the "RS-485 COMM" button.
The RS-485 COMMUNICATION SETUP is displayed.
Summary of Contents for ML-3015AS
Page 21: ...Introduction Part...
Page 22: ......
Page 30: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 52: ......
Page 53: ...Operating Part...
Page 54: ......
Page 163: ...Maintenance Part...
Page 164: ......
Page 175: ...Appendixes...
Page 176: ......