SIA
code
Definition
Description
Text message
*
ID
1
ID
2
**
XJ
Xmitter Supervision Restoral
Supervision restoral of a wireless
transmitter or wireless detector
zone name
zone nr.
XR
Xmitter Restoral
Battery restoral of
a wireless transmitter or wireless
detector
zone name
zone nr.
XS
Xmitter Supervision
Supervision
alarm of a wireless transmitter or
wireless detector
zone name
zone nr.
XT
Xmitter Trouble
Low battery alarm
of a wireless transmitter or
wireless detector
zone name
zone nr.
YR
Battery Restoral
Battery restoral
message
module name
module nr.
YT
Battery Trouble
Low battery alarm module name
module nr.
*
The contents of the text block can be transmitted only when using Alphatronics' SIA-HS protocol, not
when using the American SIA protocol.
**
The additional ID information can be transmitted only when using Alphatronics' SIA-HS protocol, not
when using the American SIA protocol.
***
Both the MA, MB, MR, MT, MU messages as well as the UA, UB, UR, UT, UM messages are
messages of zone type 5. The decision which message will be transmitted by a zone of type 5, MA or
UA, is defined in screen 8
"Medical alarm instead of technical alarm". For zones of type 7 (direct
dial control) the codes UA, UB, UR, UT, UM will always be transmitted.
The zone name, that will be transmitted when using the SIA-HS protocol, is the 16-character name as
programmed.
The ID1 information block contains, depending on the kind of event, a zone number, a module number, a
keypad number or the user code number.
The ID2 information block is used by SIA-HS only. It contains the number of the user code that was used to
bypass/unbypass a certain zone.
The number of the user code that was used is normally within the range 01 up to 98. The value 99 is used to
indicate the installer, a keyswitch or the RTC (automatic timerswitch).
AlphaVision NG installation manual Rev. 2.0 27-08-2003 Blz. 100/101