sections
Press the <#> key to change the sections this Proximity Reader is programmed to, or press the <
↑
> or the
<
↓
> keys to choose another option (outputs, features). When the <#> key is pressed, the following will
appear in the display:
NGPR2 sections
<1-8> ABCDEFGH
The text NGPR2 tells you that the features for Proximity Reader 2 can now be changed.
To change the section programming of the NG Proximity Reader, use keys <1> through <8>, where section
A is represented by key <1>, section B by key <2>, etc., to activate or deactivate a section. For instance, if
you wishes to program only section A to this Proximity Reader, press keys <2>, <3>, <4>, <5>, <6>, <7>
and <8>. The display will change to:
NGPR2 sections
<1-8> A.......
Press the <#> key when the correct sections are shown in the display. Then press the <
↓
> key to continue to
the output programming. The display will change to:
NG Prox Reader 2
outputs
Press the <#> key to change or view the output programming. The display will change to:
NGPR2 output:
RO module 0
Use the <0> through <8> keys to program the number of the RO module which is to be controlled by this
Proximity Reader. When there is no RO module in the system, or in case there is no RO module to be
controlled by this Proximity Reader, a 0 must be programmed here.
Press the <#> to confirm the correct programming. The display will change to:
NGPR2 output:
IO module 00 - 0
The Proximity Reader can control an output of any expansion module in the system. Enter the number of the
expansion module with two digits, followed by the number of the desired output. For example, if output 7 of
expansion module 5 must be activated by the Proximity Reader, enter <0>, <5>, <7>. The display will
change to:
NGPR2 output:
IO module 05 - 7
Any output of an expansion module can be programmed for this. In case output 9 of an I/O module is
programmed, the speaker output of this I/O module will generate the same sound as with the doorbell
function.
Please keep in mind that a wireless input module can be selected, but has got no outputs on the PCB!
When the desired programming is shown in the display, press the <#> key to confirm. The display will
change to:
AlphaVision NG installation manual Rev. 2.0 27-08-2003 Blz. 86/101