160
Rockwell Automation Publication 750-UM006C-EN-P - March 2022
Chapter 5
Drive Maintenance
Replace the PowerFlex Frame 2 Heatsink Fan
For information on repair or replacement of the drive heatsink fan, see
PowerFlex 750-Series Fan Replacement Kits, publication
Follow the procedure to
, follow instructions to
Remove the Front Cover on page 148
, and follow the instructions to
PowerFlex Frame 2 Drive (1EA030) on page 156
to gain access to the fan.
Replace Option Modules
For information on repair or replacement option modules, see the PowerFlex
750-Series Option Modules, publication
1. Without removing the control cables attached to the terminal blocks,
detach the terminal blocks from the options modules located in
slots 4,
5, 6, 7, or 8
.
2. Place the removed option modules in anti-static bags.
For information on repair or replacement of the option modules in the drive,
see PowerFlex 750-Series Option Modules, publication
PowerFlex 750-Series AC Drives, publication
.
TIP
In most cases, the majority of cables and wires routed into the Frame 2 drive
can remain connected while replacing the heatsink fan.
TIP
To avoid the need to rewire the terminal blocks, verify terminal screws and
wires are secure. Terminal wiring does not need to be removed to replace
option modules.
ATTENTION:
Note which slot each of the option modules was removed from.
Failure to record option module location could result in equipment failure,
software incompatibility, startup problems, or other damage.
Option Module
Slot Assignment
(1)
Variable Slot
Assignments
(2)
Catalog Number
Reference
Publication
PowerFlex-750 Series Encoder Option module
–
Slot 4
20-750-ENC-1
PowerFlex-750 Series Dual Encoder Option module
–
Slot 4
20-750-DENC-1
PowerFlex-750 Series 24V DC Transistor I/O Option module
Slot 7
–
20-750-2263C-1R2T
PowerFlex-750 Series Universal Feedback Option module
–
Slot 4 and/or Slot 5
20-750-UFB-1
PowerFlex-750 Series Axillary Power Supply
Slot 8
–
20-750-APS
PowerFlex-750 Series Network Safe Torque Off Option module
–
Slot 6
20-750-S3
PowerFlex-750 Series-Integrated Safety Function
–
Slot 6
20-750-S4
(1) This column can be used to record the physical slot assignment for the option modules.
(2) Slot assignment varies based on configuration option selected.