Rockwell Automation Publication 750-UM006C-EN-P - March 2022
201
Periodic and Preventive Maintenance
Chapter 7
enclosure plate. Cable connectors should be tightened hand-tight and
receptacles should be to the specified torque values listed in the following table.
Solid-state Devices —
Solid-state devices require a little more than a periodic
visual inspection. Inspect the printed circuit boards to determine whether they
are properly seated in the edge connectors. Board locking tabs must be in place.
Necessary replacements must be made only at the personal computer board or
plug-in component level. Do not use solvents on printed circuit boards. When
blowers are used, air filters must be cleaned or changed periodically depending
on the specific environmental conditions encountered.
Locking and Interlocking Devices
— Check these devices for proper working
condition and capability of performing their intended functions.
Terminal Designation
Description
Torque Value (lb•in)
L123
Input Power
60 ± 10%
T123
Output Power
60 ± 10%
DRB
Dynamic Brake
60 ± 10%
EMB1
400/480V AC Source Mechanical Brake
45 ± 10%
EMB2
24V DC Mechanical Brake
45 ± 10%
CP
24V DC Control Power
45 ± 10%
CPBR
24V DC Brake Power
45 ± 10%
DBRT
Brake Resistor Thermostat Temperature
45 ± 10%
SO
S0 Safety (S3)
45 ± 10%
S0
S0 Network Safety (S4)
45 ± 10%
S0
S0 Network Safety (S4 with brake)
45 ± 10%
S1
S1 Network Safety (S4)
45 ± 10%
PO
P0 Digital Input
45 ± 10%
P1
P1 Digital Input
45 ± 10%
CFBM
Allen-Bradley Servo Bulk Head Hiperface Encoder -
Bulk head adapter
11 ± 10%
Allen-Bradley Servo Bulk Head Hiperface Encoder -
Mounting screws
25 ± 10%
CPBM
Allen-Bradley Servo Motor Power and Brake - Bulk
head adapter
11 ± 10%
Allen-Bradley Servo Motor Power and Brake -
Mounting screws
25 ± 10%
ENCO
M23 Incremental Encoder
133 ± 10%
HIPSC
M23 Hiperface SC Encoder
133 ± 10%
SSIL
M23 SSI Linear Encoder
133 ± 10%
DENCO
M23 Dual Incremental Encoder - 0
133 ± 10%
DENC1
M23 Dual Incremental Encoder - 1
133 ± 10%
SSISC
M23 SSISC Rotary Encoder
133 ± 10%
ETH1
EtherNet/IP Link 1
20 ± 10%
ETH 2
EtherNet/IP Link 2
20 ± 10%
ATTENTION:
Use of other than factory recommended test equipment for
solid-state controls can result in damage to the control or test equipment or
unintended actuation of the controlled equipment.