158
Rockwell Automation Publication 750-UM006C-EN-P - March 2022
Chapter 5
Drive Maintenance
8. Without removing the control cables attached to the TB1 terminal
block, disconnect the
TB1
terminal block from the main control board.
9. Use a
#2 Pozidriv, M3 x 7
tool to remove the listed power wires.
10. Use a
7 mm hex deep socket
to remove the ground wires.
11. Remove the EMC kit. See
Replace the EMC Kit (1CH030) on
for additional information.
12. Use a
T20 torque bit
to remove the 14 screws that hold the drive to the
enclosure.
TIP
To avoid the need to rewire the terminal blocks, verify terminal screws and
wires are secure. Terminal wiring does not need to be removed to replace
the PowerFlex 755 drive.
Wire Description
Terminal Number
1EA030-R/L1
R/L1
1EA030-S/L2
S/L2
1EA030-T/L3
T/L3
1EA030-PE
PE (LEFT SIDE)
1EA030-U
U/T1
1EA030-V
V/T2
1EA030-W
W/T3
1EA030-PE
PE (RIGHT SIDE)
1EA030-BR1
BR1
1EA030-BR2
BR2
IMPORTANT
In the image, the covers are shown in place, the covers must be removed and
the terminal blocks disconnected to remove the drive.