7 Stop Codes
If a Stop condition is detected that prevents the tool from running, a code will appear on the LED
display. Any active stop conditions are also displayed on the RUN screen.
Code
Icon
Description
IO
Stopped or Disabled from
Physical 24 volt IO input
ABUS
Stopped or Disabled from
ANYBUS
MODB
Stopped or Disabled from
Modbus
EIP
Stopped or Disabled from
Ethernet IP
RTU
Stopped or Disabled from
Modbus RTU
OP
Stopped or Disabled from
Open Protocol
OP
Lost Open Protocol
Connection
REV
Disassembly Disabled
ARM
Tool Requires Arming – MFB
button configured to enable
the tool to run.
JOB
Job Sequence Complete
JOB
Job Complete
JOB
XML Count Complete
LOR
Locked on Reject
BRCD
Bar Code ID scan required to
enable tool
SRVC
Tool Disabled For Service -
Tool service or calibration
interval has expired
INVP
Invalid PSet - Parameter set
number for a non-existent
Pset has been selected to run.
Most likely via one of the
following methods:
o
Job
o
MFB
o
IO
Code
Icon
Description
INVP
PSet outside of Job -
Parameter set number outside
of the job has been selected.
Most likely via one of the
following methods:
o
MFB
o
IO
INVJ
Invalid Job - Job number for a
non-existent Job has been
selected to run. Most likely via
one of the following methods:
o
MFB
o
IO
PSET
PSet Mismatch
SPND
Spindle Not Configured –
Spindle selected to run from a
Multi-Spindle Job has not
been configured
NET
XML Disconnected
XML
Stop from XML
NOK
XML Max Rejects Exceeded
FLT
Controller Fault - Error has
been detected. See fault
code list for details