3 Initial Set Up
Step 1
Connect tool cable to Tool Connector. Cable consists of a male pin set housed in a molded 19
pin connector with a polarizing notch. Align tool cable notch with tool connector notch on
the controller and insert cable. Securely thread connector coupler to controller body.
Step 2
Repeat above process to connect tool cable to AcraDyne tool being used with the controller.
Step 3
Plug female end of power cable into Power Cable Connector.
Step 4
Plug male end of power cable into appropriate power source.
Due to a variety of 230VAC power outlets, the standard power cable plug-end provided with the
controller
may
need to be modified in order to connect to local 230Vac power outlets. AcraDyne has a
wide variety of country-specific power cord options available. Check with your authorized AcraDyne
representatives to see if your specific configuration is available. In any case, connection to local power
should be made in consultation with a qualified electrician.
Step 5
The Secondary Protective Earth Attachment needs to be clamped properly to ground.
1
Step 6
Turn controller on by pushing the Power Disconnect Switch to the POWER ON position, a light
indicates power on.
NOTE:
Warning will appear if the controller is power cycled too quickly.
If a fault appears, Power Down controller, wait a mimimum of 10
seconds between controller Power Down, and Power Up to clear error