Page
78
of
84
9 Dual-Lever Tools Requiring Two-Handed Operation
Two Handed Functionality
•
Tool will not run unless both switches are pressed within one second of each other.
•
If the one second timer times out, both switches must be released to reset the timer.
•
If either trigger is released the tool stops.
•
To restart the tool, both switches must be released and pressed within one second of each other.
NOTE:
All settings in Controller
Start Input Configuration will be ignored.
o
I/O cannot be used to start a two-handed tool.
o
Latching throttle is disabled for a two-handed tool.
•
Exceptions exist for Tubenut tool homing.
Tubenut Tool Homing Exceptions for Two-Handed Functionality
•
If controller’s tubenut homing configuration is set to RELEASE:
o
Releasing either, or both, of the levers will initiate the homing sequence.
o
Homing will continue until sequence is complete.
•
If controller’s tubenut homing configuration is set to RELEASE AND REPRESS:
o
Releasing either of the levers, then pressing both levers will initiate the homing sequence.
o
Homing will continue while both of the levers are being pressed.
o
If either lever is released, before homing is complete, tool will stop and homing will pause
until both levers are pressed.
o
To restart tool, after homing is complete, both switches must be released and pressed
within one second of each other.