4.5.1.4 Start Input Configuration
Start from IO:
Start tool through I/O from external source.
Start from Tool Buttons
: Normal operating condition: Tool lever and
MFB control tool operation.
Start from Master Tool
Tool Throttle Configuration:
Four options are available:
•
Lever or PTS (Push to Start): This the default configuration.
Pressing either the Lever or PTS will start the tool.
•
Lever and PTS (Push to Start): Both the Lever and the PTS need
to be pressed in order to start the tool.
•
Lever: Only the Lever will start the tool.
•
PTS: Only the PTS will start the tool.
Latching Options:
•
Not Latched: Start Input is not latched.
•
Latch on Time: Start Input latches if lever is pressed for a set
time.
•
Latch on MFB: Latches on the following sequence:
o
Press and hold lever.
o
Press MFB, while lever is still being held down.
o
Release the lever.
o
Release the MFB.
Latch Hold Time (s):
Amount of time (in seconds) the lever needs to
be depressed to latch throttle (if Latched on Time is selected
above).
NOTE:
Throttle will unlatch automatically at the end of the rundown or when the lever is repressed. If the
tool is installed with dual levers requiring two-handed operation, the above Start Input Configuration
settings will be ignored (see Dual Lever Two Handed Tools section).