Transducer Full Scale (Nm:
Full scale torque rating of transducer.
4.8.4 Live Tool
Shows a live view of tool transducer in volts. Voltage will be
approximately 2.0 volts (± 0.005 Vdc) when tool is at rest and torque is
zero (verify the voltage is within the green zone in the graph).
During a rundown, tool transducer voltage increases as torque
increases.
Motor Hall sensors A, B, C will be monitored along with tool throttle,
Multi-Function Button and RPM.
4.8.5 Record Logs
Logs information describing usage of controller and tools that have been used with that controller.
4.8.5.1 Change Log
Log displays changes made to tool or controller.
4.8.5.2 Information Log
Log displays all information entries.
4.8.5.3
Error Log
Log displays ONLY Error Entries.
4.8.5.4
All
Displays all Changes, Information and Error entries.