Page
18
of
84
On Add New PSet screen(below)enter appropriate
values.
PSet Number:
Current PSet to be added.
Torque Units:
Unit of measure.
In Cycle Torque:
Threshold value at which tool is “In Cycle” and results
from the Rundown will be reported.
Cycle Complete Torque:
Torque level that determines completion of a
fastening cycle.
Time Limit(s) (sec):
Maximum allowable time tool is allowed to run.
Advanced Options:
(see 4.2.3)
(
PSets
(See 3.2 Quick Setup)
Manage
(see 4.2.4 Manage PSets)
Once PSet values are entered press
to enter
Add New Stage
screen.
Add New Stage
A single stage or multiple stages build a PSet. Up to 20 stages can be
assigned per PSet.
The following stage options are available:
Once the desired stage(s) are selected and configured, press
to save stage and again to save the
PSet
and return to initial PSet menu.
Next Press
to go to the
RUN
screen or
to return to the
Home
page. The tool should now be