4.2.5.2 TC_AM Torque
Control
Angle
Monitor Stage
Control
strategy is convenient for detection of cross threaded or
stripped fasteners. Rundown is considered to be successful
(Accept) if the stage peak torque value falls within range
specified by
Torque High Limit
and
Torque
Low Limit
and final
angle value falls within the range specified by
Angle High Limit
and
Angle Low Limit
parameters.
Torque High:
Upper control limit of the rundown.
Torque Target:
Final desired torque.
Torque Low:
The lower control limit of the rundown.
Angle Bailout:
Determines when to stop the tool on angle during
any Torque Control strategy. Should be set equal to or above
High Angle. Units are degrees of rotation.
Angle High:
Maximum acceptable angle rotation in degrees.
Angle Low:
Minimum acceptable angle rotation in degrees.
Reference:
(drop down menu)
Overall Angle:
Angle is measured starting from lever/trigger
pull.
In-cycle Angle:
Angle is measured from In-Cycle torque
value (Determined in PSet screen).
Stage Angle:
Angle is measured from Reference Torque.
Reference Torque:
If Stage Angle is selected, this will be the start
point (in Torque) at which angle is monitored.
NOTE:
Set Reference Torque to zero to measure Stage Angle
from the beginning of the stage.
Max (RPM):
Tool Output speed target.
Acceleration (kRPM/s):
How quickly the tool will change speed.
The lower the value the slower the accleration ( Glossary for
detailed description).
Stage Timeout (sec):
Maximum allowable time in this stage. If
time is exceeded, the tool will stop and the Rundown will be
terminated.
TC AM Stage