4.2.3 Advanced Options
PSet Name:
Add PSet name if desired (up to 10 characters).
Thread Direction:
Defines fastening direction (default is right hand).
Re-hit/Reject Parameters:
P
revents the fastening of an already
tightened fastener. If enabled, tool will stop and the rundown will be
aborted, if the angle of rotation between the Re-hit Reference
Torque and the In-Cycle Torque is less than the Re-hit Angle Count.
NOTE:
If the attempted rundown is a Re-hit, it will not be reported or
recorded.
Re-hit Reject Enable:
Enables the feature.
Re-hit Reference Torque:
This torque value is the start of the angle
count that determines a Re-hit. (This value should be lower than the
In Cycle Torque specified in the PSet.)
Re-hit Angle Count:
If the angle count between the Re-hit
Reference
Torque
and the In Cycle Torque is less than this value, the rundown is
determined to be a Re-hit.
4.2.4 Manage PSets
Save PSets to Browser
Allows the PSet information to be saved to the local PC
connected to controller. PSet information is saved as a .txt file and
can be opened using any text editor such as WordPad. It can also
be opened with Excel. The format of the .txt file is tab separated
values.
Export PSets to Browser
Save the PSets as a database file to the PC connected to
controller. These PSets can later be imported to another controller.
Import PSets from Browser
Import previously exported PSets to controller.
Delete PSets
Enables deletion of selected PSets.
Save/Export/Import USB
Same as above using a USB Memory Stick