4.8.2 Controller Status
Shows “Live” status of controller, voltages, active faults and temperature.
Power Supplies:
Alarm icon will appear on controller console and under
“Active Faults” (see below) if any of these values are out of range:
•
5 VDC :
Represents voltage from 5V power supply powering
controller electronics.
•
9 VDC:
Represents voltage from 9V power supply powering Tool
electronics.
•
24 VDC:
Represents voltage from 24V power supply. Value is
reported as on or off (.0 – 24.0 volts) and is for external use via
24V I/O port.
•
1.8 VDC:
Represents controller electronics internal 1.8V Bus
voltage.
•
3.3V DC:
Represents controller electronics internal 3.3V Bus
voltage.
•
DC Bus:
Value represents voltage supplied to tool motor while
running.
CPU Temperature (deg C):
Represents temperature inside controller
measured in Celsius.
Active Faults:
Any tool/ controller faults will be shown in this area.
4.8.3 Tool Overview
This “read only
”
screen gives an overview of the tool connected to
the controller. The information is stored in the memory on the Tool ID
board (TID).
Model Number:
Model number of tool connected to controller.
Serial Number:
Serial number of tool connected to controller.
Cycle Count:
Number of fastening cycles tool has performed since
counter was reset.
Maximum Speed (RPM):
Maximum free speed of tool output.
Maximum Torque (Nm):
Maximum torque output of tool.
The following information is used internally by AcraDyne Technicians
and not generally relevant to the end user:
Gear Ratio After Tranducer:
Any gearing between transducer and
tool output.
Gear Inversion:
1= Tool Output rotates same direction as motor.
–1= Tool Output rotates in opposite direction as motor. (Example:
Tubenut tools typically show –1 for gear inversion)
External Multiplier:
Gear ratio of external “after market” multiplier.
Pulses/Rev Output:
Number of motor hall pulses that occurs per one
revolution of motor Output.