Page
54
of
84
4.6.1 Tool Setup
Allows user to make changes to Tool Setup.
Model Number:
Tool model number of tool connected to controller.
Tool ID:
Serial Number of current tool connected to controller.
Cycle Count:
Total number of cycles since last reset.
Multiplier:
Configures tool to include gearing added to the base
model. Units: Gear Ratio * 100 (Example: Adding a multiplier with a gear
ratio of 5:1, Multiplier setting = 5).
Gear Inversion:
1 = tool Output rotates same direction as motor and
–1= tool Output rotates in opposite direction as motor.
Tube Nut Parameters
“see Gen IV IEC manual section 14 TubeNut Tool Set up Details for more
information
Obstruction Torque (in*Lb):
First 90° of rotation in the fastening direction.
Cycle will be aborted if this torque is exceeded. If the tool rotates 90°
and stops without any obstruction, the value is too low.
Open Loop (in*Lb):
After reaching the open position, this is the “hold at
Home” torque preventing socket from bouncing to a partially closed
position. This torque should be set to a value slightly less than the
tubenut Home torque.
Home (in*Lb):
In the reverse direction, reaching this torque indicates to
controller that socket is in open position. If socket does not attempt to
return to open position, this value is too low. AcraDyne recommends
starting at approximately 12 in-lbs.
4.6.2 Service Log
Service Parameters are stored in memory of tool and can be viewed
in this screen. The ‘Next Service Cycle’ or ‘Next Service Date’ will turn
red if value entered is exceeded.