MAINTENANCE
202
Condor-UM-2011-21-R0-en-us-20210108
6.45 Winter storage
Procedure:
1.
Rinse the sprayer with clean water and drain the water. The clean water tank and the spray
tank must be empty.
2.
Dirt retains moisture and causes rust. Clean the sprayer with a pressure washer. Do not
point the water jet at bearings or electrical components.
3.
Park the sprayer in a dry, frost-free area. Do not park the sprayer near fertilizer.
4.
Disconnect the batteries from the machine (
86
).
5.
Place the sprayer on blocks to take the load off the tires.
6.
Drain the water condensate from the compressed air tanks.
7.
Repair paint damage.
8.
Protect bare metal parts with an anti-corrosive.
9.
Do the points under “At the start of winter storage” in the Maintenance schedule (
152
).
10.
Order all parts that have to be replaced. Install the parts when they arrive.
Extra procedure if the sprayer is not parked in a dry, frost-free area:
1.
Unscrew the pipes.
2.
With electric section valves: unscrew the pipes below the section valves.
3.
Operate all valves 10 times.
4.
Drain all the pipes.
5.
Remove the batteries and store them in a dry, frost-free area.
Summary of Contents for Condor C03
Page 14: ...14 Condor UM 2011 21 R0 en us 20210108 ...
Page 18: ...SAFETY 18 Condor UM 2011 21 R0 en us 20210108 ...
Page 19: ...SAFETY Condor UM 2011 21 R0 en us 20210108 19 ...
Page 54: ...START UP 54 Condor UM 2011 21 R0 en us 20210108 ...
Page 144: ...OPERATION 144 Condor UM 2011 21 R0 en us 20210108 ...
Page 218: ...TROUBLESHOOTING 218 Condor UM 2011 21 R0 en us 20210108 ...
Page 220: ...ENVIRONMENT 220 Condor UM 2011 21 R0 en us 20210108 ...
Page 222: ...DISPOSAL PHASE 222 Condor UM 2011 21 R0 en us 20210108 ...
Page 232: ...SPECIFICATIONS 232 Condor UM 2011 21 R0 en us 20210108 ...
Page 233: ...APPENDICES Condor UM 2011 21 R0 en us 20210108 233 11 APPENDICES ...
Page 248: ...APPENDICES 248 Condor UM 2011 21 R0 en us 20210108 ...