Programming Command Reference
5
N9360A Multi UE Tester W-CDMA Programming Manual
5-67
IDLE+DPCH(PN9)+OCNS
: Outputs
IDLE
(without S-CCPCH), RMC
12.2kbps(PN9) and OCNS.
IDLE+DPCH(PN15)+OCNS
: Outputs
IDLE
(without S-CCPCH),
RMC 12.2kbps(PN15) and OCNS.
This is automatically set to
IDLE
when the screen is changed to
the [TX Analyzer] screen while Modulation on the [Signal
Generator] screen is set to
OFF
. (There is no
OFF
setting in TX
Analyzer.)
This query command returns the set modulation.
RF Signal Output
TXANalyzer:RFOUtput ON|OFF|1|0
TXANalyzer:RFOUtput?
This command sets RF Signal Output status. The parameter is
ON
(1) or
OFF
(0). At preset, this is set to
OFF
. This works with RF
Output on the [Signal Generator] screen.
Averaging
TXANalyzer:AVERage OFF|<int>
TXANalyzer:AVERage?
This command sets whether or not to activate the averaging.
The parameter is
OFF
or
<int>
for the number of averaging
times. The allowable range of
<int>
is from
2
to
99
. At preset,
this is set to
OFF
.
This query command returns the set averaging.
TX Power Measurement
TXANalyzer:TXPower:STATe ON|OFF|1|0
TXANalyzer:TXPower:STATe?
This command sets whether or not to execute the TX Power
measurement. The parameter is
ON
(1) or
OFF
(0). At preset, this
is set to
ON
.
Summary of Contents for N9360A
Page 1: ...Agilent Technologies Agilent N9360A Multi UE Tester W CDMA Programming Manual...
Page 4: ...1 4 N9360A Multi UE Tester W CDMA Programming Manual 1 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 8: ...8 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 12: ...6 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...