5-68
N9360A Multi UE Tester W-CDMA Programming Manual
5
Programming Command Reference
This query command returns the setting of the TX Power
measurement with integer value of
1
or
0
. The meaning of the
return value is same as that of the command parameter.
Frequency Error
TXANalyzer:FREQuency:STATe ON|OFF|1|0
TXANalyzer:FREQuency:STATe?
This command sets whether or not to execute the Frequency
Error measurement. The parameter is
ON
(1) or
OFF
(0). At
preset, this is set to
ON
.
This query command returns the setting of the Frequency Error
measurement with integer value of
1
or
0
. The meaning of the
return value is same as that of the command parameter.
EVM
TXANalyzer:EVM:STATe ON|OFF|1|0
TXANalyzer:EVM:STATe?
This command sets whether or not to execute the EVM
measurement. The parameter is
ON
(1) or
OFF
(0). At preset, this
is set to
ON
.
This query command returns the setting of the EVM
measurement. The meaning of the return value is same as that
of the command parameter.
ACLR
TXANalyzer:ACLR:STATe ON|OFF|1|0
TXANalyzer:ACLR:STATe?
This command sets whether or not to execute the ACLR
measurement. The parameter is
ON
(1) or
OFF
(0). At preset, this
is set to
ON
. This command is valid only when the W07 option is
installed in the Tester. If the W07 option is not installed in the
Tester, an execution error occurs.
This query command returns the setting of the ACLR
measurement. The meaning of the return value is same as that
of the command parameter.
Summary of Contents for N9360A
Page 1: ...Agilent Technologies Agilent N9360A Multi UE Tester W CDMA Programming Manual...
Page 4: ...1 4 N9360A Multi UE Tester W CDMA Programming Manual 1 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 8: ...8 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 12: ...6 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...