background image

5-72

N9360A Multi UE Tester W-CDMA Programming Manual

5

Programming Command Reference

 

<real 3>

 (up to 4 letters) is the measured data ranging 

from 

0.00

 to 

9.99

 in MHz. If measurement result is out of 

range or OBW is not measured, the value 

9.99

 is returned.

This command is valid only when the W07 option is installed in 
the Tester. If the W07 option is not installed in the Tester, an 
execution error occurs.

Signal Generator Subsystem

The Signal Generator subsystem commands are used to set and 
read the controls and parameters of the Signal Generator 
functions.

RFGenerator Subsystem Command Reference

Radio System

RFGenerator:RFORmat W_CDMA

RFGenerator:RFORmat? 

This command selects a Radio System to be tested. Only 

W-CDMA

 

is available. 

RFCH

RFGenerator:CHANnel <int>

RFGenerator:CHANnel?

This command sets the channel number. The allowable range 
and preset values are as follows:

The range of the value is same as that of the command 
parameter.

RFGenerator:CHANnel <int 1>,<int 2>

Table 5-13 

RFCH Allowable Range and Preset Value

Band

Allowable Range

Preset Value

1

10550 to 10850

10562

6

4375 to 4425, 1037, 1062

4387

Summary of Contents for N9360A

Page 1: ...Agilent Technologies Agilent N9360A Multi UE Tester W CDMA Programming Manual...

Page 2: ...nd or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If software is for use in t...

Page 3: ...Refer also to the N9360A W CDMA Programming Manual for information about the test functions of W CDMA Wideband Code Division Multiple Access Notation The following notations are used in this manual Ex...

Page 4: ...1 4 N9360A Multi UE Tester W CDMA Programming Manual 1 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 5: ...2 Safety Summary 2 2 Safety Notices 2 2 Warning Label 2 2 General 2 3 When Operating The Tester 2 3 3 Preparing for Use Equipment for Automated Test System 3 2 Ethernet 3 2 GP IB Option 3 2 RS 232C Op...

Page 6: ...ference 5 13 Command Reference for Configuration Test Sequence Screen 5 16 Command Reference for Configuration Test Condition Screen 5 28 Command Reference for File Management Screen 5 37 TESTs Subsys...

Page 7: ...s 6 11 Test Result 6 11 MS Information Screen 6 13 Manual Test Screens 6 14 Stand by Screens 6 14 Measuring Screens 6 15 Test Result 6 15 MS Information Screen 6 16 SMS Screen 6 16 TX Analyzer Screens...

Page 8: ...8 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 9: ...3 Table 5 7 Power Control Level Parameter and Preset Value for Connection 5 53 Table 5 8 Power Control Level Parameter and Preset Value for Connection continued 5 53 Table 5 9 RFCH Allowable Range and...

Page 10: ...on Command Cross Reference 6 16 Table 6 15 SMS Command Cross Reference 6 16 Table 6 16 Command Cross Reference for Stand by Screen 6 17 Table 6 17 TPOWer TXAMplitude Command Summary 6 18 Table 6 18 RF...

Page 11: ...4 18 7 Sample Program Figure 7 1 Sample Program Screen 7 3 8 Syntax Diagrams Figure 8 1 IEEE Common Commands 8 2 Figure 8 2 Top Menu Commands 8 3 Figure 8 3 DISPlay Subsystem 8 4 Figure 8 4 Configure...

Page 12: ...6 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 13: ...1 1 Agilent Technologies 1 Legal Information Warranty 1 2 Technology Licenses 1 2 Restricted Rights Legend 1 2 Service And Support 1 3 Agilent On The Web 1 3 Agilent By Phone 1 3...

Page 14: ...erms in the separate agreement shall control Technology Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accordance with...

Page 15: ...e link to Test Measurement Select your country from the drop down menus The Web page that appears next has contact information specific for your country Agilent By Phone If you do not have access to t...

Page 16: ...1 4 N9360A Multi UE Tester W CDMA Programming Manual 1 Legal Information THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 17: ...2 1 Agilent Technologies 2 Caution and Safety Requirements Safety Summary 2 2 Safety Notices 2 2 Warning Label 2 2 General 2 3 When Operating The Tester 2 3...

Page 18: ...ning Label A warning label is stuck on the front panel of the Tester Do not remove damage or modify the warning label CAUTION A CAUTION notice denotes a hazard It calls attention to an operating proce...

Page 19: ...rument covers Component replacement and internal adjustments must be made only by qualified service personnel Products that appear damaged or defective should be made inoperative and secured against u...

Page 20: ...2 4 N9360A Multi UE Tester W CDMA Programming Manual 2 Caution and Safety Requirements THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 21: ...for Use Ethernet 3 2 GP IB Option 3 2 RS 232C Option 3 3 Ethernet 3 5 GP IB 3 5 RS 232C 3 5 This chapter describes a quick overview of how to set up an automated test system with the Agilent N9360A Mu...

Page 22: ...to connect the HUB the controller and the Tester An RF cable to connect the RF signals from or to the mobile phone under test the Antenna Coupler Agilent CAU 17 to connect RF signals from or to the m...

Page 23: ...2 below RS 232C Option The following equipments are required to construct an automated test system using RS 232C The Agilent N9360A Multi UE Tester A system controller with the RS 232C interface An R...

Page 24: ...3 4 N9360A Multi UE Tester W CDMA Programming Manual 3 Preparing for Use Figure 3 3 Typical Setup for Automated Test System Serial Interface...

Page 25: ...an IEEE 488 GP IB connector use the IEEE 488 GP IB cable between the controller PC and the Tester RS 232C A DB 9 male connector Option E01 is provided with the Tester as the serial interface to a con...

Page 26: ...DCD RX TX DTR GND DSR RTS CTS RI DCD RX TX DTR GND DSR RTS CTS RI Tester Cable PC DB 9 Female DB 9 Male DB 9 Female DB 9 Male 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 DCD RX TX DTR GND DSR RTS CTS RI Teste...

Page 27: ...verview of the Ethernet Interface 4 4 Overview of the GP IB Interface 4 6 Overview of the RS 232C Serial Interface 4 7 Programming Guidelines 4 10 Typical Programming Flow for the Tester 4 10 Why Woul...

Page 28: ...ial type of command Queries instruct the instrument to respond data available to the controller Query mnemonics always end with a question mark Preset A default value or status when the Tester is ship...

Page 29: ...follows the CONFigure portion of the statement with no separating space A separating space is legal only between the command and its argument In this example the portion following the PKEY is the arg...

Page 30: ...d continue indicates the line does not end and continue to the next line For example ABC DEF Is same as follows ABC DEF In addition all commands parameters and mark to use in the programming are the A...

Page 31: ...tted to the Tester is LF fixed The TCP port number is 10123 fixed Refer to the following procedure to set the Ethernet configuration Step 1 On the Initial screen press the Config softkey to obtain the...

Page 32: ...set The preset settings and other choices are as follows The terminator outputted from the Tester can be changed as specified in Table 4 2 The terminator inputted to the Tester is LF fixed If EOI is s...

Page 33: ...ivate the configuration Overview of the RS 232C Serial Interface Settings for the Serial Interface Refer to the documentation on your controller programming language and I O card to configure the seri...

Page 34: ...ed Refer to the following procedure to set the serial port configuration Step 1 On the Initial screen press the Config softkey to obtain the Configuration screen Table 4 3 Serial Port Configuration It...

Page 35: ...Tester set the Xcontrol on the Configuration screen to Xon Xoff When the controller receives the Xoff decimal value of 19 stop transmitting data When the controller receives the Xon decimal value of...

Page 36: ...t ends To check the measurement status read the Status Byte Register using the STB query command and check the Data Ready Bit Bit 0 and the Measuring Status Bit Bit 1 When testing by the Automatic Tes...

Page 37: ...e the Manual Test mode test sets as follows Send Command to the Tester TEST MAN RFCH CHAN 9800 Send Command to the Tester TEST MAN BSCT RMC Step 5 Create an instruction message as follows for the oper...

Page 38: ...resend the query Else proceed to the next step Step 9 Read the test results of Peak TX Power for example as follows Send Query Command to the Tester TEST MAN RES TXP Display Message on the PC Peak TX...

Page 39: ...posed of five physical registers one condition register two transition registers one event enable register and one event register However the Standard Event Status Register is composed of an event ena...

Page 40: ...without erasing its contents Setting and Querying the Registers Each bit in a register is represented by a numerical value based on its location as shown in Figure 4 4 To enable or disable a particula...

Page 41: ...le and bit 5 Standard Event Status Summary Bit as shown in Figure 4 6 Figure 4 5 Overall Status Byte Register System 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Measurement Data Ready Bit Measurin...

Page 42: ...er D e c i m a l V a l u e 7 6 5 4 3 2 1 0 U n u s e d U n u s e d S t a n d e r d E v e n t S t a t u s S u m m a r y M e s s a g e A v a i l a b l e M A V U n u s e d U n u s e d M e a s u r i n g S...

Page 43: ...D e p e n d e n t E r r o r Q u e r y E r r o r U n u s e d O p e r a t i o n C o m p l e t e 7 6 5 4 3 2 1 0 ESR Table 4 5 Status Byte Register Bit Description 0 If all pending operations is complete...

Page 44: ...o corresponding bit of the Standard Event Status Enable Register Send the ESE int command where int is the sum of the decimal values of the bits you want to enable For example to inform the Power On a...

Page 45: ...r due to a program mnemonic is too long 113 Command error due to an undefined header 120 Command error due to a numeric data error 123 Command error due to an exponent is too large 124 Command error d...

Page 46: ...4 20 N9360A Multi UE Tester W CDMA Programming Manual 4 Programming Command Guidelines THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 47: ...omatic Test 5 39 Command Reference for Stand by Measuring Screens 5 39 Command Reference for Test Result Signaling and RF Test 5 41 Command Reference for RF Test Result 5 43 TESTs Subsystem for Manual...

Page 48: ...fication information about the manufacturer name model number serial number and the revision number of the firmware Reset RST This command executes the self test routine and resets the Tester to the i...

Page 49: ...ESR The range of a value is from 0 to 255 Information contained in the Standard Event Status Register is as follows bit 0 1 Operation Complete bit 1 2 Unused bit 2 4 Query Error bit 3 8 Device Depende...

Page 50: ...Reference bit 3 8 Unused bit 4 16 Message Available bit 5 32 Standard Event Status Summary bit 6 64 Unused bit 7 128 Unused For detailed information refer to Status Byte Register on page 15 Instrument...

Page 51: ...alues int 1 and string 2 for error numbers and error messages Refer to Table 4 6 on page 19 Lock System Panel SYSTem KLOCk SYSTem KLOCk ON OFF 1 0 This command sets all the panel keys setting to ON 1...

Page 52: ...matic Test Stand by screen is currently displayed the Sequence number 1 or 2 is displayed When other screen is displayed 0 is returned Top Menu Screen DISPlay INIT This command selects the Top Menu sc...

Page 53: ...Commands Printer Control CONFigure PRINter PMG800 USBMemory CONFigure PRINter This command sets the output direction of the Print Screen The choices are PMG800 and USBMemory At preset this is set to...

Page 54: ...f the calendar in the Tester int YYYY is year within the range from 1990 to 2037 int MM is month within the range from 1 to 12 and int DD is day within the range from 1 to 31 This query command return...

Page 55: ...tic boot If this is set to GSM or WCDMA the Tester starts automatic boot with the GSM application or the W CDMA application respectively Preinstalled Option must be installed in the Tester to boot GSM...

Page 56: ...UTO STBY Automatic Test Stand by Screen MAN STBY Manual Test Stand by Screen MAN SMS Manual Test SMS Screen TXAN STBY TX Analyzer Stand by Screen RFG Signal Generator Screen CONF Configuration Screen...

Page 57: ...by screen TX Analyzer Screen DISPlay TXANalyzer STBY This command selects the TX Analyzer Stand by screen Signal Generator Screen DISPlay RFGenerator This command selects the Signal Generator screen...

Page 58: ...nd Manual Test Test Sequence Screen DISPlay CONFigure SEQuence This command selects the Configuration Test Sequence screen The parameters and controls on this screen set the test sequence of Automatic...

Page 59: ...the attenuation function setting by integer value of 1 or 0 Attenuation Level Setting for Input Signal CONFigure LOSS RFIN real 1 real 2 real 3 real 4 real 5 real 6 CONFigure LOSS RFIN This command s...

Page 60: ...ontrol CONFigure BEEPer ON OFF 1 0 CONFigure BEEPer This command sets the beeper function to ON 1 or OFF 0 If this is set to ON there is beep for each step of operation If this is set to OFF beep is s...

Page 61: ...d parameter Panel Key Control CONFigure PKEY UNLOCK LOCK CONFigure PKEY This command sets the panel key control to UNLOCK or LOCK At preset this is set to UNLOCK If this is set to LOCK only Automatic...

Page 62: ...query command returns the selected Radio System with strings Sequence Number CONFigure SEQuence NO 1 2 CONFigure SEQuence NO This command specifies a sequence number The sequence number specified her...

Page 63: ...urementbslevel real CONFigure SEQuence MEASurementbslevel This command specifies the amplitude BS Level for MAX TX Power Inner Loop Power EVM and Origin Offset measurement in each band set by the Band...

Page 64: ...this is set to 10 FreqError BS Level CONFigure SEQuence FRQbslevel real CONFigure SEQuence FRQbslevel This command specifies the amplitude BS Level of the Tester for frequency error test in each band...

Page 65: ...NFigure SEQuence VARiable RFCH CHANnel2 CONFigure SEQuence VARiable RFCH CHANnel3 int 1 int 2 CONFigure SEQuence VARiable RFCH CHANnel3 CONFigure SEQuence VARiable RFCH CHANnel4 int 1 int 2 CONFigure...

Page 66: ...H1 This query command returns the setting of the Open Loop TX Power test with integer The meaning of the return value is same as that of the command parameter Inner Loop Power CONFigure SEQuence INNEr...

Page 67: ...sum of the values of all the 6 bits as follows bit 0 1 For testing RFCH1 bit 1 2 For testing RFCH2 bit 2 4 For testing RFCH3 bit 3 8 For testing RFCH4 bit 4 16 For testing RFCH5 bit 5 32 For testing R...

Page 68: ...EQuence EVM int CONFigure SEQuence EVM This command sets whether to include the EVM test in the test sequence int is the sum of the values of all the 6 bits as follows bit 0 1 For testing RFCH1 bit 1...

Page 69: ...r Run and 0 for skip At preset this is set to 63 This query command returns the setting of Sensitivity BER test with integer The meaning of the return value is same as that of the command parameter RF...

Page 70: ...al 1 Band 1 and real 6 Band 6 respectively real 2 real 3 real 4 and real 5 are unused Set to 0 0 The allowable range is from 9 9 to 9 9 in 0 1 steps At preset this is set to 0 0 This query command ret...

Page 71: ...Figure SEQuence LOSS RFOUT CHANnel6 real 1 real 2 real 3 real 4 real 5 real 6 CONFigure SEQuence LOSS RFOUT CHANnel6 This command sets the RF output path loss on each RFCH real 1 Band 1 and real 6 Ban...

Page 72: ...d returns the setting of MS Call with integer value of 1 or 0 The meaning of the return value is same as that of the command parameter Talk Test MS Call CONFigure SEQuence SIGNaling TALK ON OFF 1 0 CO...

Page 73: ...e as that of the command parameter BS Call RMC CONFigure SEQuence SIGNaling BSCAll RMC ON OFF 1 0 CONFigure SEQuence SIGNaling BSCAll RMC This command sets whether or not to include the BS Call RMC in...

Page 74: ...t This command selects a Radio System to be tested Only W CDMA is available Band CONFigure CONDition BAND int CONFigure CONDition BAND This command sets the Band number The parameter is 1 or 6 At pres...

Page 75: ...this is set to 10 This query command returns the set number of the frames for BER test with integer The range of the value is same as that of the command parameter Open Loop TX Power CONFigure CONDiti...

Page 76: ...h limits for Inner Loop Power DownMax Test in each band set by the Band command described on page 28 The allowable range is from 99 99 to 99 99 dB in 0 01 steps At preset this is set to 2 00 dB and 0...

Page 77: ...power 10SlotsDown This command sets the low and high limits for the test in each band set by the Band command described on page 28 The allowable range is from 99 99 to 99 99 dB in 0 01 steps At preset...

Page 78: ...e is same as that of the command parameter Frequency Error Limit CONFigure CONDition LIMit FREQuency real LO real HI CONFigure CONDition LIMit FREQuency This command sets the low and high limits for F...

Page 79: ...each band set by the Band command described on page 28 The allowable range is from 99 99 to 0 00 in 0 01 steps At preset this is set to 32 00 dB This query command returns the set high limit of Origin...

Page 80: ...escribed on page 28 The allowable range is from 99 99 to 0 00 dB in 0 01 steps At preset this is set to 40 00 dB This command is valid only when the W07 option is installed in the Tester If the W07 op...

Page 81: ...mmand sets a signaling pattern The allowable range is from 1 to 255 in 1 step At preset this is set to 1 This query command returns the set signaling pattern with integer The range of the value is sam...

Page 82: ...HKey Type This command selects the type of Authentication Key among ORG STD and USER At preset this is set to ORG This query command returns the set type of Authentication Key with string CONFigure CO...

Page 83: ...n the front panel or rear panel Save File CONFigure FILE SAVE string FILENAME string COMMENT This command saves the current settings of the Tester into the HDD or USB memory device FILENAME accepts up...

Page 84: ...emory device The return format is int TOTAL int FILENO_1 string FILENAME_1 string DATE_1 string TIME_1 string COMMENT_1 int FILENUMBER_n string FILENAME_n string DATE_n string TIME_n and string COMMEN...

Page 85: ...rn the settings of those controls and parameters Screen Mode TESTs AUTO SCReen SIMPlified DETailed VALue TESTs AUTO SCReen This command selects the screen mode The parameter is SIMPlified DETailed or...

Page 86: ...el6 int 1 int 2 TESTs AUTO VARiable RFCH CHANnel6 These commands set a Band and a variable uplink channel number for RFCH The measurement on the RFCH is skipped if these are set to 1 99999 is shown in...

Page 87: ...s of 12 bits as follows bit 0 1 Location Update bit 1 2 MS Call bit 2 4 Talk bit 3 8 MS Release bit 4 16 BS Call AMR bit 5 32 Talk bit 6 64 BS Release bit 7 128 BS Call RMC bit 8 256 RF Test bit 9 512...

Page 88: ...alk bit 3 8 MS Release bit 4 16 BS Call AMR bit 5 32 Talk bit 6 64 BS Release bit 7 128 BS Call RMC bit 8 256 RF Test bit 9 512 BS Release bit 10 1024 Abort Each bit is set to 0 if the test is pass or...

Page 89: ...Open Loop TX Power Measurement TESTs AUTO RESults OPENpower1 This query command returns the measurement result values int 1 int 2 and real 3 for RFCH 1 int 1 1 digit is 0 if measurement result is wit...

Page 90: ...MIN is not measured the value 99 99 is returned Inner Loop Power Measurement Down MAX TESTs AUTO RESults INNErpower1 DownMAX TESTs AUTO RESults INNErpower2 DownMAX TESTs AUTO RESults INNErpower3 DownM...

Page 91: ...n dB If measurement is out of range or Inner Loop Power is not measured the value 99 99 is returned Inner Loop Power Measurement Up MAX TESTs AUTO RESults INNErpower1 UpMAX TESTs AUTO RESults INNErpow...

Page 92: ...e test result for the pass 0 or fail 1 real 3 up to 6 letters is the measured data ranging from 99 99 to 99 99 in dB If measurement result is out of range or Inner Loop Power 10 Slots Down in not meas...

Page 93: ...and real 3 for each channel int 1 1 digit is 0 if measurement result is within the measurement range or 1 if measurement result is out of range or Max TX Power is not measured int 2 1 digit is the te...

Page 94: ...TO RESults EVM4 TESTs AUTO RESults EVM5 TESTs AUTO RESults EVM6 This query command returns the EVM measurement result values int 1 int 2 and real 3 for each channel int 1 1 digit is 0 if measurement r...

Page 95: ...e value 99 99 is returned TESTs Subsystem for Manual Test This function allows you to execute real time measurements Command Reference for Stand by Screens These commands are used to set the controls...

Page 96: ...set to 1 at preset int 2 is a variable uplink channel number and set to 9612 at preset The allowable ranges are as follows At start up of the Tester the queries in int 1 and int 2 format are returned...

Page 97: ...y int 1 real 2 TESTs MANual RFCH FREQuency This command sets a Band and frequency for RF uplink in Stand by or Connection status When RFCH is set in the Connection status handover will starts However...

Page 98: ...ommand sets the amplitude BS Level of output signal from the Tester The allowable range is from 110 0 to 50 0 dBm in 0 1 step At preset this is set to 50 0 dBm This query command returns the set ampli...

Page 99: ...mobile phone continuously HOLD Remains output power level of the mobile phone int Increases or decreases output power level of the mobile phone by int dB This setting is valid in the Connection status...

Page 100: ...her or not to enable OCNS The parameter is ON 1 or OFF 0 This is valid in the Connection RMC status Also this is reset to OFF 0 when the status becomes Stand by This query command returns the setting...

Page 101: ...Power test with integer value of 1 or 0 The meaning of the return value is same as that of the command parameter Frequency Test TESTs MANual FREQuency STATe ON OFF 1 0 TESTs MANual FREQuency STATe Thi...

Page 102: ...ATe This command sets whether or not to execute the CPICH RSCP measurement The parameter is ON 1 or OFF 0 At preset this is set to ON If this is set to ON in Connection status the softkey for CPICH RS...

Page 103: ...s the connection by manual response during response time after MS Call initiation Signaling State TESTs MANual SIGNaling STATe This query command returns the test step currently executed for a test cy...

Page 104: ...ed value is a sum of the values of all the 10 bits as follows ranging from 0 to 511 bit 0 1 Location Update bit 1 2 MS Call bit 2 4 MS Release bit 3 8 BS Call AMR bit 4 16 BS Call RMC bit 5 32 BS Rele...

Page 105: ...nge or PRACH Power is not measured int 2 1 digit is the test result for the pass 0 or fail 1 real 3 up to 5 letters is the measured data ranging from 99 9 to 99 9 in dBm If measurement result is out o...

Page 106: ...al RESults EVM This query command returns the EVM measurement result values int 1 int 2 and real 3 Each value is separated by a comma int 1 1 digit is 0 if measurement result is within the measurement...

Page 107: ...2 1 digit is the test result for the pass 0 or fail 1 real 3 up to 7 letters is the measured data ranging from 0 00 to 100 00 in If measurement result is out of range or BER is not measured the value...

Page 108: ...etters Or this command returns Emergency Call in the case of an emergency call Command Reference for SMS Screen SMS MT TESTs MANual SMS ASC string TESTs MANual SMS ASC This command sets a SMS MT send...

Page 109: ...type of the data ASC or BIN ASC indicates text data ASCII and BIN indicates binary data int 2 indicates the value of the Coding Scheme int 3 indicates the data length When ASCII data is received up t...

Page 110: ...FCH CHANnel int 1 int 2 TXANalyzer RFCH CHANnel This command sets a channel for Band and RF uplink on the Stand by screen int 1 is a band and set to 1 at preset int 2 is a variable uplink channel numb...

Page 111: ...the RFCH with real The range of the value is same as that of the command parameter TXANalyzer RFCH FREQuency int 1 real 2 TXANalyzer RFCH FREQuency This command specifies a Band and frequency for RF...

Page 112: ...t signal from the Tester applied to the mobile phone under test in each Band The allowable range is from 110 0 to 20 0 dBm in 0 1 steps At preset this is set to 50 0 dBm This query command returns the...

Page 113: ...OUtput ON OFF 1 0 TXANalyzer RFOUtput This command sets RF Signal Output status The parameter is ON 1 or OFF 0 At preset this is set to OFF This works with RF Output on the Signal Generator screen Ave...

Page 114: ...s that of the command parameter EVM TXANalyzer EVM STATe ON OFF 1 0 TXANalyzer EVM STATe This command sets whether or not to execute the EVM measurement The parameter is ON 1 or OFF 0 At preset this i...

Page 115: ...ent result values int 1 int 2 and real 3 Each value is separated by a comma int 1 1 digit is 0 if measurement result is within the measurement range or 1 if measurement result is out of range or TX Po...

Page 116: ...l 1 real 3 up to 7 letters is the measured data ranging from 0 00 to 100 00 in If measurement result is out of range or EVM is not measured the value 99 99 is returned Origin Offset Measurement TXANal...

Page 117: ...sult values int 1 int 2 and real 3 int 1 1 digit is 0 if measurement result is within the measurement range or 1 if measurement result is out of range or ACLR DSB 10Hz is not measured int 2 1 digit is...

Page 118: ...ubsystem commands are used to set and read the controls and parameters of the Signal Generator functions RFGenerator Subsystem Command Reference Radio System RFGenerator RFORmat W_CDMA RFGenerator RFO...

Page 119: ...with int 1 and int 2 format is performed the format of the query returns to int 1 and int 2 format This query command returns the set Band and Channel number of RFCH with integer The range of the val...

Page 120: ...of the query changes to int format If the setting with int 1 and int 2 format is performed the format of the query returns to int 1 and int 2 format This query command returns the set Band and Freque...

Page 121: ...RMC 12 2kbps PN9 and OCNS IDLE DPCH PN15 OCNS Outputs IDLE without S CCPCH RMC 12 2kbps PN15 and OCNS This works with Modulation on the TX Analyzer screen This is automatically set to IDLE when the sc...

Page 122: ...uery command returns a set of values int 1 and string 2 for error numbers and error messages Refer to Table 4 6 for the listings of the error messages Lock System Panel SYSTem KLOCk ON OFF 1 0 SYSTem...

Page 123: ...and steps are as follows This query command returns the stored values with integer Softkey Memory BS Level SYSTem MEMory AMPLitude real 1 real 2 real 3 real 4 SYSTem MEMory AMPLitude This command sto...

Page 124: ...mmand immediately starts a measurement When measurement is completed the Tester s state becomes idle Trigger Mode TRIGger MODE SINGle CONTinuous TRIGger MODE This command sets the trigger mode to eith...

Page 125: ...11 Test Result 6 11 MS Information Screen 6 13 Manual Test Screens 6 14 Stand by Screens 6 14 Measuring Screens 6 15 Test Result 6 15 MS Information Screen 6 16 SMS Screen 6 16 TX Analyzer Screens 6 1...

Page 126: ...and Summary Item Command Identification Query IDN Reset RST Operation Complete OPC OPC Clear Status CLS Standard Event Status Enable ESE int ESE Event Status Register Query ESR Status Byte Register Qu...

Page 127: ...int MM int DD CONF DATE Time CONF TIME int HH int MM CONF TIME Autoboot CONF AUTOB NONE GSM WCDMA int CONF AUTOB Table 6 2 Top Menu Command Summary Item Command Table 6 3 DISPlay Subsystem Command Sum...

Page 128: ...and so forth which are fundamentally required to operate the Tester File Management DISP CONF FILE Table 6 3 DISPlay Subsystem Command Summary Item Command Table 6 4 CONFigure Subsystem Command Summa...

Page 129: ...Item Command Table 6 5 SEQuence Command Summary Item Command Radio System CONF SEQ RFOR W CDMA OFF CONF SEQ RFOR Sequence Number CONF SEQ NO 1 2 CONF SEQ NO Band CONF SEQ BAND int CONF SEQ BAND CONF...

Page 130: ...N4 int 1 int 2 CONF SEQ VAR RFCH CHAN4 CONF SEQ VAR RFCH CHAN5 int 1 int 2 CONF SEQ VAR RFCH CHAN5 CONF SEQ VAR RFCH CHAN6 int 1 int 2 CONF SEQ VAR RFCH CHAN6 Open Loop TX Power CONF SEQ OPEN int CONF...

Page 131: ...EQ LOSS RFIN CHAN5 CONF SEQ LOSS RFIN CHAN6 real 1 real 2 real 3 real 4 real 5 real 6 CONF SEQ LOSS RFIN CHAN6 RF Output Attenuation CONF SEQ LOSS RFOUT CHAN1 real 1 real 2 real 3 real 4 real 5 real 6...

Page 132: ...BSCA AMR ON OFF 1 0 CONF SEQ SIGN BSCA AMR Talk Test AMR CONF SEQ SIGN TALK AMR ON OFF 1 0 CONF SEQ SIGN TALK AMR BS Call RMC CONF SEQ SIGN BSCA RMC ON OFF 1 0 CONF SEQ SIGN BSCA RMC RF Test CONF SEQ...

Page 133: ...l LO real HI CONF COND LIM INNE Inner Loop Power 10 slots Up CONF COND LIM INNE 10SU real LO real HI CONF COND LIM INNE 10SU Max TX Power CONF COND LIM TXP real LO real HI CONF COND LIM TXP Frequency...

Page 134: ...COND LDEL Connection Wait CONF COND CON int CONF COND CON Algorithm of power control CONF COND TPCA 1 2 CONF COND TPCA Authentication Key CONF COND AUTHK T ORG STD USER CONF COND AUTHK T CONF COND AU...

Page 135: ...R SIMP DET VAL TEST AUTO SCR Caller ID TEST AUTO CALL ID string TEST AUTO CALL ID RFCH TEST AUTO VAR RFCH CHAN1 int 1 int 2 TEST AUTO VAR RFCH CHAN1 TEST AUTO VAR RFCH CHAN2 int 1 int 2 TEST AUTO VAR...

Page 136: ...E6 DMAX Up MIN Measurement TEST AUTO RES INNE1 UMIN TEST AUTO RES INNE2 UMIN TEST AUTO RES INNE3 UMIN TEST AUTO RES INNE4 UMIN TEST AUTO RES INNE5 UMIN TEST AUTO RES INNE6 UMIN Up MAX Measurement TEST...

Page 137: ...AUTO RES FREQ3 TEST AUTO RES FREQ4 TEST AUTO RES FREQ5 TEST AUTO RES FREQ6 EVM Measurement TEST AUTO RES EVM1 TEST AUTO RES EVM2 TEST AUTO RES EVM3 TEST AUTO RES EVM4 TEST AUTO RES EVM5 TEST AUTO RES...

Page 138: ...1 int 2 TEST MAN RFCH CHAN Frequency TEST MAN RFCH FREQ real TEST MAN RFCH FREQ int 1 real 2 TEST MAN RFCH FREQ BS Level TEST MAN AMPL real TEST MAN AMPL BS Call Type TEST MAN BSCT AMR RMC TEST MAN B...

Page 139: ...and Cross Reference for Stand by Screen Item Command Table 6 12 Command Cross Reference for Measuring Screen Item Command Power Control Level TEST MAN PLEV UP DOWN CONTUP CONTDOWN HOLD int TEST MAN PL...

Page 140: ...RES OOFF BER Measurement TEST MAN RES BER CPICH RSCP Measurement TEST MAN RES CPRS Table 6 13 Command Cross Reference for Manual Test Result Item Command Table 6 14 MSINformation Command Cross Refere...

Page 141: ...H TXAN RFCH CHAN int TXAN RFCH CHAN int 1 int 2 TXAN RFCH CHAN Frequency TXAN RFCH FREQ real TXAN RFCH FREQ int 1 real 2 TXAN RFCH FREQ Amplitude TXAN AMPL real TXAN AMPL Modulation TXAN MOD IDLE IDLE...

Page 142: ...Item Command TX Power Measurement TXAN RES TXP Frequency Error Measurement TXAN RES FREQ EVM Measurement TXAN RES EVM Origin Offset Measurement TXAN RES OOFF ACLR DSB 5MHz TXAN RES ACLR5 ACLR DSB 10M...

Page 143: ...ger function of the Tester Table 6 19 HCOPy Subsystem Command Summary Item Command Dump Screen Image HCOP SDUM Table 6 20 SYSTem Subsystem Command Summary Item Command System Error SYST ERR Lock Syste...

Page 144: ...6 20 N9360A Multi UE Tester W CDMA Programming Manual 6 Programming Command Summary Abort TRIG ABOR Table 6 21 TRIGger Subsystem Command Summary Item Command...

Page 145: ...ent 7 5 Automatic Test Function 7 6 Manual Test Function 7 10 TX Analyzer Function 7 14 This chapter explains an example program contained in the CD R to be used for testing a W CDMA mobile phone with...

Page 146: ...1 NOTE This program only describes the programming flow Perform the following operations if you want to execute the program Change Configuration of the Tester Ethernet GP IB RS 232C GP IB control supp...

Page 147: ...he configuration of the interface is shown in Figure 7 1 2 Test buttons Starts each test by pressing a button 3 Status field Displays the status and results of the test This program runs with the conf...

Page 148: ...functions The function to manipulate the status field display is described in Table 7 2 Refer to source code file sample bas in the CD R for detail operation GP IB GP IB Address 2 1 EOI Off Off RS 23...

Page 149: ...The functions provided by the GP IB interface card manufacture is used to initialize open and close GP IB port In this sample program driver software Niglobal bas Vbib 32 bas provided by National Ins...

Page 150: ...the status field 1 Public Sub Automatic_Sample 2 Dim value 3 4 ClrStatus 5 6 Tester Status 7 value Split ENTER IDN 8 AddStatus value 0 9 AddStatus value 1 10 AddStatus value 2 11 AddStatus value 3 12...

Page 151: ...tus Please off hook 40 WAIT TEST AUTO MEAS SIGN STAT 32 41 AddStatus Talk 42 If MsgBox Talk Pass vbYesNo vbYes Then 43 OUTPUT TEST AUTO MEAS TALK PASS 44 Else 45 OUTPUT TEST AUTO MEAS TALK FAIL 46 End...

Page 152: ...dB IIf value 1 And 1 FAIL PASS 66 value Split ENTER TEST AUTO RES INNE CStr channel 10SU 67 AddStatus ILP 10Slots Up value 2 dB IIf value 1 And 1 FAIL PASS 68 value Split ENTER TEST AUTO RES TPOW CStr...

Page 153: ...lue screen 26 Starts the Automatic Test 27 Directs a user Turn on the mobile phone 28 Waits until the location update is completed 29 Directs the user Please MS Call 30 Waits until the state is Talk t...

Page 154: ...and judgment result of ILP Up Min in the status field 62 Queries the measurement result of ILP Up Max 63 Displays the measurement value and judgment result of ILP Up Max in the status field 64 Queries...

Page 155: ...15 OUTPUT CONF LOSS ON 16 OUTPUT CONF LOSS RFIN 5 0 0 0 0 0 0 0 0 0 5 0 17 OUTPUT CONF LOSS RFOU 5 0 0 0 0 0 0 0 0 0 5 0 18 OUTPUT CONF COND 3GPP 2 19 20 Measure Setup 21 OUTPUT TEST MAN BSCT RMC 22 O...

Page 156: ...ower value 2 dBm IIf value 1 And 1 FAIL PASS 42 43 Freq Error 44 value Split ENTER TEST MAN RES FREQ 45 AddStatus Frequency Error value 2 Hz IIf value 1 And 1 FAIL PASS 46 47 EVM 48 value Split ENTER...

Page 157: ...the Loss RF OUT field 18 Sets the 3GPP System 21 Sets the BS Call Type to RMC 22 Sets the Band and RFCH 23 Completes settings and waits until the Manual screen is displayed 24 Directs a user Turn on...

Page 158: ...tus value 2 11 AddStatus value 3 12 13 OUTPUT RST 14 44 Queries the measurement result of Frequency Error 45 Displays the measurement value and judgment result of Frequency Error in the status field 4...

Page 159: ...DLE 25 OUTPUT TXAN RFOU ON 26 27 Measure 28 OUTPUT TXAN RFCH CHAN 1 9600 29 OUTPUT TRIG IMM 30 WAIT STB 0 31 value Split ENTER TXAN RES TXP 32 AddStatus Peak TX Power value 2 dBm IIf value 1 And 1 FAI...

Page 160: ...plitude BS Level 21 Sets the 3GPP System 24 Sets the Modulation to IDLE 25 Sets the RF OUTPUT to ON 29 Sets the Band and RFCH 29 Starts the measurement 30 Waits until the measurement is completed 31 Q...

Page 161: ...1 Agilent Technologies 8 Syntax Diagrams In this Appendix the syntax diagram for each subsystem commands is shown These diagrams use a graphical format to represent the hierarchical structure of syste...

Page 162: ...h the other section in this guide or the User s Guide for detailed information Syntax Diagrams Represents a command A query command trails a question mark Indicates that a colon must be used between t...

Page 163: ...nu Commands ERRor sp bool SYSTem KLOCK KLOCK INIT DISPlay CONFigure DISPlay CONFigure PRINter PRINter BEEPer BEEPer ROSCillator ROSCillator sp enum bool sp sp enum AUTOBoot AUTOBoot sp enum init2 DATE...

Page 164: ...lti UE Tester W CDMA Programming Manual 8 Syntax Diagrams Figure 8 3 DISPlay Subsystem INIT AUTO STBY MANual FILE DISPlay sp enum STBY TXANalyzer RFGenerator CONFigure CONFigure CONDition SEQuence STB...

Page 165: ...RINter BEEPer BEEPer PKEY PKEY ROSCillator sp enum bool sp enum sp RFIN LOSS LOSS LOSS RFIN RFOUt RFOUt DATE DATE TIME TIME bool sp long1 sp long5 long1 sp long5 sp intY intM intD sp intH intM CONDiti...

Page 166: ...real LO sp real HI real LO sp real HI real LO sp real HI real LO 10SlotsDown sp real HI real LO sp real HI real LO 10SlotsDown 10SlotsUp 10SlotsUp TXPower TXPower FREQuency FREQuency EVM EVM sp real H...

Page 167: ...p string sp Key Key Type Type CONnectionwait int sp CONnectionwait b WCDMAMODe enum sp WCDMAMODe sp BAND sp int BAND BSLEvel sp int BSLEvel BAND BAND SEQuence RFORmat RFORmat enum NO NO sp enum 3GPPsy...

Page 168: ...ivity OPENpower sp int OPENpower VARiable sp sp int1 int1 sp int1 sp int1 sp int1 CHANnel1 CHANnel1 CHANnel2 CHANnel2 CHANnel3 CHANnel3 CHANnel4 CHANnel4 CHANnel5 CHANnel5 int2 int2 int2 int2 int2 RFC...

Page 169: ...4 CHANnel5 CHANnel5 CHANnel6 CHANnel6 real6 real6 real6 real6 real6 real6 RFOUT c a d SIGNaling LOCUpdate LOCUpdate BSCAll sp enum sp bool MSCAll sp bool MSCAll TALK sp bool TALK BSCAll AMR AMR sp int...

Page 170: ...Diagrams Figure 8 9 Configure Subsystem continued a d f RFTEST RFTEST sp bool BSCAll sp bool BSCAll RMC RMC TALK sp bool AMR AMR TALK FILE SAVE RECall DELete stringFILENAME sp sp sp stringFILENAME st...

Page 171: ...HANnel1 sp int1 int2 CHANnel2 CHANnel2 sp int1 int2 CHANnel3 CHANnel3 sp int1 int2 CHANnel4 CHANnel4 sp int1 int2 CHANnel5 CHANnel5 sp int1 int2 CHANnel6 CHANnel6 sp int1 int2 INNErpower1 DownMIN INNE...

Page 172: ...Erpower2 UpMAX INNErpower3 UpMAX INNErpower4 UpMAX INNErpower5 UpMAX INNErpower6 UpMAX INNErpower1 10SlotDown INNErpower2 10SlotDown INNErpower3 10SlotDown INNErpower4 10SlotDown INNErpower5 10SlotDow...

Page 173: ...UE Tester W CDMA Programming Manual 8 13 Figure 8 12TESTs Subsystem for Automatic Test continued a SENSitivity BER1 BER2 BER3 BER4 BER5 BER6 MSINformation IMSI MSINformation IMEI MSINformation DIAL E...

Page 174: ...sp int2 a b sp sp enum real PLEVel PLEVel AMPLitude AMPLitude int sp int1 FREQuency FREQuency real2 CHANnel int sp sp real FREQuency STATe sp FREQuency STATe sp SENSitivity FRAMe bool FRAMe sp sp boo...

Page 175: ...for Manual Test continued a b MSINformation IMSI IMEI DIAL CPichRScp STATe STATe MEASure bool sp Signaling RESults EVM FRQuency TXPower PRACHPower BER OriginOFFset CPichRScp LOCupdate BSCall BSReleas...

Page 176: ...YPE enum 2 sp enum ECIOR ECIOR sp enum 1 MEASType MEASType int 2 sp int HARQRetrans HARQRetrans sp int UECATEgory UECATEgory sp bool OCNS OCNS sp bool HSDLError HSDLError a b STATe sp STATe bool THROU...

Page 177: ...itude sp enum MODulation MODulation sp bool RFOUtput RFOUtput FREQuency FREQuency sp int1 real2 CHANnel sp int FREQuency sp real sp bool TXPower STATe STATe sp bool OBW STATe STATe sp bool FREQuency S...

Page 178: ...CHANnel sp enum sp int1 int2 FREQuency FREQuency sp int1 real2 CHANnel sp int AMPLitude AMPLitude MODulation MODulation sp real sp enum RFOUtput RFOUtput sp bool FREQuency sp real MODulation sp enum 1...

Page 179: ...ter W CDMA Programming Manual 8 19 Figure 8 19System Subsystem ERRor sp bool SYSTem KLOCK KLOCK MEMory CHANnel CHANnel AMPLitude AMPLitude sp int1 int4 sp int1 int4 RBT Figure 8 20TRIGer Subsystem IMM...

Page 180: ...8 20 N9360A Multi UE Tester W CDMA Programming Manual 8 Syntax Diagrams THIS PAGE IS INTENTIONALLY LEFT BLANK...