Programming Command Reference
5
N9360A Multi UE Tester W-CDMA Programming Manual
5-71
•
<int 1>
(1 digit) is
0
if measurement result is within the
measurement range, or
1
if measurement result is out of
range or ACLR DSB 5MHz is not measured.
•
<int 2>
(1 digit) is the test result for the pass (0) or fail (1).
•
<real 3>
(up to 6 letters) is the measured data ranging
from
-99.99
to
0.00
in dB. If measurement result is out of
range or ACLR DSB 5MHz is not measured, the value
-99.99
is returned.
This command is valid only when the W07 option is installed in
the Tester. If the W07 option is not installed in the Tester, an
execution error occurs.
ACLR DSB 10MHz Measurement
TXANalyzer:RESults:ACLR10mhz?
This query command returns a set of test result values,
<int
1>
,
<int 2>
, and
<real 3>
.
•
<int 1>
(1 digit) is
0
if measurement result is within the
measurement range, or
1
if measurement result is out of
range or ACLR DSB 10Hz is not measured.
•
<int 2>
(1 digit) is the test result for the pass (0) or fail (1).
•
<real 3>
(up to 6 letters) is the measured data ranging
from
-99.99
to
0.00
in dB. If measurement result is out of
range or ACLR DSB 10MHz is not measured, the value
-99.99
is returned.
This command is valid only when the W07 option is installed in
the Tester. If the W07 option is not installed in the Tester, an
execution error occurs.
OBW Measurement
TXANalyzer:RESults:OBW?
This query command returns a set of test result values,
<int
1>
,
<int 2>
, and
<real 3>
. Each value is separated by a
comma.
•
<int 1>
(1 digit) is
0
if measurement result is within the
measurement range, or
1
if measurement result is out of
range or OBW is not measured.
•
<int 2>
(1 digit) is the test result for the pass (0) or fail (1).
Summary of Contents for N9360A
Page 1: ...Agilent Technologies Agilent N9360A Multi UE Tester W CDMA Programming Manual...
Page 4: ...1 4 N9360A Multi UE Tester W CDMA Programming Manual 1 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 8: ...8 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 12: ...6 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...