5-18
N9360A Multi UE Tester W-CDMA Programming Manual
5
Programming Command Reference
This command specifies the amplitude (BS Level) of the Tester
for Bit Error Ratio (BER) test in each band set by the
command described on
. The allowable range is from
-110.0
to
-20.0
(dBm) in
0.1
steps. At preset, this is set to
-106.7
(dBm).
BER Frame
CONFigure:SEQuence:SENSitivity:FRAMe <int>
CONFigure:SEQuence:SENSitivity:FRAMe?
This command specifies the number of the frames for BER. The
allowable range is from
1
to
4100
(frames) in
1
step. At preset,
this is set to
10
.
FreqError BS Level
CONFigure:SEQuence:FRQbslevel <real>
CONFigure:SEQuence:FRQbslevel?
This command specifies the amplitude (BS Level) of the Tester
for frequency error test in each band set by the
command
. The allowable range is from
-110.0
to
-20.0
(dBm) in
0.1
steps. At preset, this is set to
-50.0
(dBm).
RF Signal Output Mode
CONFigure:SEQuence:RFOUtput AUTO|ON
CONFigure:SEQuence:RFOUtput?
This command specifies RF Output in Automatic Test. At preset,
this is set to
ON
. The parameter is
AUTO
or
ON
. At preset, this is
set to
ON
.
This query command returns the RF signal output setting with
string of
AUTO
or
ON
.
Wait before Paging
CONFigure:SEQuence:WaitBeforePaging <int>
CONFigure:SEQuence:WaitBeforePaging?
Summary of Contents for N9360A
Page 1: ...Agilent Technologies Agilent N9360A Multi UE Tester W CDMA Programming Manual...
Page 4: ...1 4 N9360A Multi UE Tester W CDMA Programming Manual 1 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 8: ...8 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 12: ...6 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...