5-42
N9360A Multi UE Tester W-CDMA Programming Manual
5
Programming Command Reference
All Tests Results (Summary)
TESTs:AUTO:RESults:ALL?
This query command returns summary of the test results wit h
integer value of
<int 1>
and
< int 2>
. Each value is separated
by a comma.
•
<int 1>
contains test results by sum of the value of 11 bits
as follows.
bit 0(1): Location Update
bit 1(2): MS Call
bit 2(4): Talk
bit 3(8): MS Release
bit 4(16): BS Call(AMR)
bit 5(32): Talk
bit 6(64): BS Release
bit 7(128): BS Call(RMC)
bit 8(256): RF Test
bit 9(512): BS Release
bit 10(1024): Abort
Each bit is set to
0
if the test is pass or skipped, or each bit is set
to
1
if the test is fail.
If there are no test results, all bits are set to
1
, the value
2047
is
returned.
•
<int 2>
contains test results by sum of the value of 12 bits
as follows.
bit 0(1): Open Loop TX Power
bit 1(2): ILP(Down Min)
bit 2(4): ILP(Down Max)
bit 3(8): ILP(Up Min)
bit 4(16): ILP(Up Max)
bit 5(32): ILP(10s lots Down)
bit 6(64): ILP(10s lots Up)
bit 7(128): Max TX Power
Summary of Contents for N9360A