Maintaining the GC
Consumables and Parts for General GC Maintenance
24
Maintaining Your GC
Consumables and Parts for General GC
Maintenance
lists consumable parts for the hydrogen sensor module accessory and for general GC
maintenance.
Table 2
Consumables and parts for general GC maintenance
Description
Part number
Hydrogen sensor parts
Calibration gas cylinder, 2 percent hydrogen gas in 17 L compressed air
5190-6890
Cylinder stand with locking screw
1400-3583
Pressure regulator, with gage
G3440-80153
Fittings and hardware
Fittings kit, 1/8-inch brass, 20/pk
5080-8750
Plug, 1/8-inch brass 6/pk
5180-4124
Tee, 1/8-inch brass 2/pk
5180-4160
Union, 1/8-inch brass 2/pk
5180-4127
Cross, union 1/8-inch brass
0100-0161
GC Supply Gas Installation Kit with Gas Purifiers
19199N
Installation kit for GCs without gas purifiers
19199M
PTFE tape
0460-1266
Copper tubing, 1/8-inch 12 ft.
5021-7107
Copper tubing, 1/8-inch od, 50 ft
5180-4196
Gas regulators
Regulator, 2-stage, brass body, stainless steel diaphragms, 125 psi max, CGA350, hydrogen,
argon/methane, with 1/8-inch fitting. For 1/4-inch tubing purchase a 1/4-inch adapter.
5183-4642
Regulator, 2-stage, brass body, stainless steel diaphragms, 125 psi max, CGA346, air, with 1/8-inch
fitting. For 1/4-inch tubing purchase a 1/4-inch adapter.
5183-4641
Regulator, 2-stage, brass body, stainless steel diaphragms, 125 psi max, CGA590, industrial air, with
1/8-inch fitting. For 1/4-inch tubing purchase a 1/4-inch adapter.
5183-4645
Regulator, 2-stage, brass body, stainless steel diaphragms, 125 psi max, CGA580, helium, argon,
nitrogen, 1/8-inch fitting. For 1/4-inch tubing purchase a 1/4-inch adapter.
5183-4644
Regulator, 2-stage, brass body, stainless steel diaphragms, 125 psi max, CGA540, oxygen, 1/8-inch
fitting. For 1/4-inch tubing purchase a 1/4-inch adapter.
5183-4643
Gas Clean Filters
Gas Clean connecting unit, 1-position), 1/4-inch
CP7980
Gas Clean connecting unit, 1-position), 1/8-inch
CP7988
Gas Clean connecting unit, 2-position), 1/4-inch
CP738406
Summary of Contents for 8890
Page 1: ...Agilent 8890 Gas Chromatograph Maintaining Your Gas Chromatograph GC ...
Page 8: ...8 Maintaining Your GC ...
Page 22: ...2 Removing Covers To Remove the Electronics Cover 22 Maintaining Your GC ...
Page 142: ...8 Maintaining the MMI To Bakeout Contaminants from the MMI 142 Maintaining Your GC ...
Page 178: ...10 Maintaining the VI To Bakeout Contaminants from the VI Inlet 178 Maintaining Your GC ...
Page 208: ...12 Maintaining the TCD To Bakeout Contaminants from the TCD 208 Maintaining Your GC ...
Page 240: ...14 Maintaining the ECD To Bakeout the ECD 240 Maintaining Your GC ...
Page 264: ...16 Maintaining EPC Modules Installing or Replacing Frits in the PCM 264 Maintaining Your GC ...
Page 276: ...17 Maintaining a Valve To Install the Upper Valve Box 276 Maintaining Your GC ...