10 Maintaining the VI
Consumables and Parts for the Volatiles Interface
164
Maintaining Your GC
Consumables and Parts for the Volatiles Interface
See the Agilent catalog for consumables and supplies for a more complete listing, or visit the
Agilent Web site for the latest information (
Table 27 Parts for the VI
Description
Part number
Clamping plate
G2319-20540
Volatiles interface
G2319-60505
Long column nut (65 mm)
G3504-20504
Nut, for transfer, pressure sensing, or split vent line
19258-20830
Ferrule, for transfer, pressure sensing, or split vent line
19258-20870
Split vent trap PM kit, single cartridge
5188-6495
Table 28 Nuts, ferrules, and hardware for capillary columns
Column id (mm)
Description
Typical use
Part number/quantity
.530
Ferrule, Vespel/graphite, 0.8-mm id
0.45-mm and 0.53-mm capillary columns
5062-3512 (10/pk)
Ferrule, graphite, 1.0-mm id
0.53-mm capillary columns
5080-8773 (10/pk)
Ferrule, graphite, 0.8-mm id
0.53-mm capillary columns
500-2118 (10/pk)
Column nut, finger-tight (for
0.53-mm columns)
Connect column to inlet or detector
5020-8293
.320
Ferrule, Vespel/graphite, 0.5-mm id
0.32-mm capillary columns
5062-3514 (10/pk)
Ferrule, graphite, 0.5-mm id
0.1-mm, 0.2-mm, 0.25-mm, and 0.32-mm
capillary columns
5080-8853 (10/pk)
Column nut, finger-tight (for
.100- to .320-mm columns)
Connect column to inlet or detector
5020-8292
.250
Ferrule, Vespel/graphite, 0.4-mm id
0.1-mm, 0.2-mm, and 0.25-mm capillary
columns
5181-3323 (10/pk)
Ferrule, graphite, 0.5-mm id
0.1-mm, 0.2-mm, 0.25-mm, and 0.32-mm
capillary columns
5080-8853 (10/pk)
Column nut, finger-tight (for
.100- to .320-mm columns)
Connect column to inlet or detector
5020-8292
.100 and .200
Ferrule, Vespel/graphite, 0.37-mm id
0.1-mm and 0.2-mm capillary columns
5062-3516 (10/pk)
Ferrule, Vespel/graphite, 0.4-mm id
0.1-mm, 0.2-mm, and 0.25-mm capillary
columns
5181-3323 (10/pk)
Ferrule, graphite, 0.5-mm id
0.1-mm, 0.2-mm, 0.25-mm, and 0.32-mm
capillary columns
5080-8853 (10/pk)
Ferrule, graphite, 0.4-mm id
500-2114 (10/pk)
Column nut, finger-tight (for .100- to
.320-mm columns)
Connect column to inlet or detector
5020-8292
Summary of Contents for 8890
Page 1: ...Agilent 8890 Gas Chromatograph Maintaining Your Gas Chromatograph GC ...
Page 8: ...8 Maintaining Your GC ...
Page 22: ...2 Removing Covers To Remove the Electronics Cover 22 Maintaining Your GC ...
Page 142: ...8 Maintaining the MMI To Bakeout Contaminants from the MMI 142 Maintaining Your GC ...
Page 178: ...10 Maintaining the VI To Bakeout Contaminants from the VI Inlet 178 Maintaining Your GC ...
Page 208: ...12 Maintaining the TCD To Bakeout Contaminants from the TCD 208 Maintaining Your GC ...
Page 240: ...14 Maintaining the ECD To Bakeout the ECD 240 Maintaining Your GC ...
Page 264: ...16 Maintaining EPC Modules Installing or Replacing Frits in the PCM 264 Maintaining Your GC ...
Page 276: ...17 Maintaining a Valve To Install the Upper Valve Box 276 Maintaining Your GC ...