![Agilent Technologies 8702D Installation Manual Download Page 239](http://html.mh-extra.com/html/agilent-technologies/8702d/8702d_installation-manual_2867953239.webp)
6-73
Performance Tests – Option 011
Performance Test Records - Option 011
Test 2. Source Power, Range, Linearity and Accuracy (Power Level Accuracy)
CW Frequency (MHz)
Path Loss
(dB)
Calibrated
Power
Level (dB)
Measured
Value (dB)
Power
Level
Accuracy
(dB)
Spec. (dB)
Meas.
Uncer.
(dB)
Source Output Power
Level = +10 dBm
0.300
_______
_______
_______
_______
± 1.0
± 0.15
20.000
_______
_______
_______
_______
± 1.0
± 0.10
50.000
_______
_______
_______
_______
± 1.0
± 0.10
100.000
_______
_______
_______
_______
± 1.0
± 0.10
200.000
_______
_______
_______
_______
± 1.0
± 0.10
500.000
_______
_______
_______
_______
± 1.0
± 0.10
1 000.000
_______
_______
_______
_______
± 1.0
± 0.10
2 000.000
_______
_______
_______
_______
± 1.0
± 0.10
3 000.000
_______
_______
_______
_______
± 1.0
± 0.15
Option 006
4 000.000
_______
_______
_______
_______
± 1.0
± 0.18
5 000.000
_______
_______
_______
_______
± 1.0
± 0.18
6 000.000
_______
_______
_______
_______
± 1.0
± 0.18
Summary of Contents for 8702D