ADTECH 4 series CNC System (maintainance Manual)
27
:
7.3
Alarm processing
If alarm occurs, please refer to the alarm code to confirm the failure reason.
➢
When alarm occurs, if the system isn‘t reset, the alarm will constantly prompt no
matter whether the alarm still exists, so as to avoid the conditions that alarm causes
system suspended, but can‘t find the reason.
If the error is caused by data setting, modify the data, and then press [Reset] to clear
the alarm info.
When alarm occurs, please check and remove the alarm if there are several alarms
that occur at the same time. Please refer to the alarm info in the Diagnosis menu for
details. When the alarms are eliminated, please press [Reset] to clear the alarm.
7.4
Self-diagnosis function
The CNC system may stop even when there is no alarm, this maybe he system is executing certain
processes. Then you can check with the self-diagnosis function.
The step of self-diagnosis as follows:
⑴
In the main menu, press [Dgnos] to enter the diagnosis interface;
⑵
Select [Input], or select [Output]
⑶
Output diagnosis: In edit mode, press the ―
←
‖,―
→
‖,―
↑
‖,―
↓
‖keys to select the output port, and press
[EOB] to switch the output level of corresponding output port;
⑷
Input diagnosis: When certain input signal is vactive, the corresponding area flashes on the screen.
1052
chuck signal alarm detect
Summary of Contents for 4 Series
Page 1: ...1 ADTECH 4 SERIES CNC MAINTAINANCE USER MANUAL ...
Page 65: ...ADTECH 4 series CNC System maintainance Manual 61 Instant ...
Page 110: ...ADTECH 4 series CNC System maintainance Manual 106 12 1 2 49serise Mounting dimensions ...
Page 125: ...ADTECH 4 series CNC System maintainance Manual 121 12 3 2 Main Power connection diagram ...
Page 126: ...ADTECH 4 series CNC System maintainance Manual 122 12 3 3 Servo drive connection diagram ...
Page 127: ...ADTECH 4 series CNC System maintainance Manual 123 12 3 4 Step connection diagram ...