ADTECH 4 series CNC System (maintainance Manual)
127
12.3.6
ET102A PCB board
Note :the 24V and GND are the power supply for the limit and home sensors .the MAX current output is
200MA
ET102A definition chart
port
J38
J38
J38
J38
J38
J38
J38
J38
J38
J38
J38
J38
J38
region
POWER
IN03-IN00
POWER
IN07-IN04
POWER
definition
24V+
GND
IN00
IN01
IN02
IN03
24V+
GND
IN04
IN05
IN06
IN07
24V+
function
24V+
24V-
IN00
IN01
IN02
IN03
24V+
24V-
IN04
IN05
IN06
IN07
24V+