Page 30 May 2014 – TD 293 OPERATING MANUAL – SmartGuard 5100/5120/5300/5320
Either selection allows USB configuration. As long as USB is connected it will prevent configuration through
any other connection.
When using an USB connection, you also need to download Windows Mobile Device Center (Windows Vista,
and Microsoft Windows 7) or Microsoft ActiveSync (Windows XP or earlier operating systems).
Windows Mobile Device Center and ActiveSync act as device management and data synchronization
between a Windows Mobile-based device and a computer.
Note! Changing the setting from remote (not USB) may result in loosing the configuration connection, e.g.
at a COM configuration connection to switch to LAN server only. If you don’t have LAN you need to use
USB to reset to the COM port.
A new window displays your changes. Press
Next
to confirm changes, and to start the update process.
4.2.2
Communication device
Only accessible if activated in
Device Layout < Device Layout < Communications
, refer chapter 6.7 and
TN363 for more information,
Open
Device Configuration > System Configuration
. Select the communication device to be configured
.
Which settings that applies depends on the selected protocol, refer protocol description.
AADI Real-Time protocol
:
Select recorder group index for the sensors to be transmitted. Next, check to enable data, refer Figure 4-10.
Figure 4-10 AADI Real-Time protocol
AADI Pseudo-binary Protocol/AADI Ascii Protocol
:
Select recorder group index for the sensors to be transmitted. Next, check to enable data. The number of
parameters to be transmitted is given as the last digit below the data parameter lists, refer Figure 4-13. To
add a new parameter: press
New
, select sensor source and parameter from the lists. Press the
First/Previous/Next/Last
button to view selected data parameters to be transmitted. Press
Remove
to
delete data parameter. Do similar for system parameters to be transmitted.