Page 28 May 2014 – TD 293 OPERATING MANUAL – SmartGuard 5100/5120/5300/5320
4.1.1
Multi Group Recorder
Open
Device configuration >
Deployment Settings > Multi Group
Recorder
First enable which of the groups you
want to use by ticking
Enable recorder
group
.
For each recorder group you may select
to enable real-time output, storage to
SD card, start recording automatically
at power up, and to include system
parameters. Select also if changing
interval shall be allowed from the
recorder panel, refer chapter 2.1.
Press
Add/Remove Sensors…
to move
a sensor to or from that group: select
the sensor, hold and drag the sensor
into the
Group Members
list or to the
Available Sensors
list.
Note! Sensors that are moved from
one recorder group must be placed
into another group to be recorded.
Each sensor presents its processing
time, to help you set the right
recording interval for each group.
Some sensors may be tied together so
that they must be moved as a group;
e.g. all the legacy AADI –sensors will
appear as one united group of sensors.
Figure 4-6 Multi group recorder.
Figure 4-7 Edit recorder group.