Interfaces (IEEE option L45-O1) LMG450
186
:VOLTage
:WAVeform
:WIRing
:ZPReject
10.2.10.4.3.1 :AUTO
IAM
SCPI:
:SENSe:CURRent:RANGe:AUTO <NRi>
SHORT: IAM <NRi>
ID:
n/a
Mode:
All
Type:
long int
Suffix:
1...4
Value:
0, 1
List:
n/a
Unit:
n/a
Group:
n/a
Reads and sets the status of the autorange function:
‘0’ or ‘MANUAL’ for manual range selection
‘1’ or ‘AUTO’ for automatic range selection [*RST default value]
10.2.10.4.3.2 :LINTern?
IILS?
SCPI:
:SENSe:CURRent:RANGe:LINTern?/qonly/
SHORT: IILS/qonly/
ID:
n/a
Mode:
All
Type:
float
Suffix:
1...4
Value:
n/a
List:
n/a
Unit:
A
Group:
n/a
Reads a list with the available ranges. You get several numbers which are separated by colons
‘,’. The first number defines the number of following numbers. If you have selected external
sensors, you get the list of their ranges.
10.2.10.4.3.3 [:UPPer]
IRNG
RngI
SCPI:
:SENSe:CURRent:RANGe[:UPPer] <NRf>
SHORT: IRNG <NRf>
ID:
RngI
Mode:
All
Type:
float
Suffix:
1...4
Value:
n/a
List:
n/a
Unit:
A
Group:
n/a
Reads and sets the range for the current measurement. The parameter is the nominal value of
the range.
10.2.10.4.4 :SCALe
ISCA
Iscal
SCPI:
:SENSe:CURRent:SCALe <NRf>
SHORT: ISCA <NRf>
ID:
Iscal
Mode:
All
Содержание LMG450
Страница 1: ...4 Channel LMG450 Power Meter User manual Status 2009 02 17...
Страница 2: ......
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 18: ......
Страница 22: ......
Страница 36: ......
Страница 76: ......
Страница 102: ......
Страница 112: ......
Страница 118: ......
Страница 124: ......
Страница 230: ......
Страница 240: ......
Страница 270: ...System design LMG450 270 14 2 Functional block diagram LMG450 Figure 47 Functional block diagram LMG450...
Страница 292: ......