![YOKOGAWA AE100D Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/yokogawa/ae100d/ae100d_instruction-manual_911083059.webp)
IM 1E7B0-02E
4-12
4. INSTALLATION
4.3.4
Nominal Diameter 15 mm
(0.5in.) to 400 mm (16in.) Flange
Type
IMPORTANT
Please use appropriate bolts and nuts according
to process connection. Please use compressed
non-asbestos fiber gasket, PTFE gasket or the
gasket which has equal elasticity. In case of
optional code/FRG, please use rubber gasket or
others which has equal elasticity. Be sure the
inner diameter of the gasket does not protrude to
inner piping.(Refer to Table 4.3.8)
(1) Mounting Direction
Please mount the Magnetic Flowmeter matching the
flow direction of the fluid to be measured with the
direction of the arrow mark on the flowmeter.
IMPORTANT
If it is impossible to match the direction, please
never remodel to change direction of the con-
verter. In case the measuring fluid flows against
the arrow direction, please refer to the section
6.3.6 or 7.2.8 Reversing Flow Direction.
(2) Tightening Nuts
Please tighten the bolts according to Torque Values in
Table 4.3.9. In case of PVC piping, please select
optional code/FRG, use rubber gasket and tighten with
the torque value in Table 4.3.10.
CAUTION
In case of PFA lining type as the lining material
is Fluorocarbon PFA, it is possible that bolts
loose by its character as time passes. Please
tighten the nuts regularly.
Please be sure to tighten the bolts following
prescribed torque values. Please tighten the
flange bolts diagonally with the same torque
values, step by step up to the prescribed torque
value.
Flanges(Flowmeter side)
Gaskets(two)
Flanges(Pipe side)
Bolts
Nuts
Please use appropriate bolts and nuts
according to process connection.
Figure 4.3.5
Mounting Procedure (Size: 15 mm (0.5in.) to 400 mm (16in.))