![YOKOGAWA AE100D Скачать руководство пользователя страница 118](http://html.mh-extra.com/html/yokogawa/ae100d/ae100d_instruction-manual_911083118.webp)
10. OUTLINE
IM 1E7B0-02E
10-8
Optional Specifications
Item
Specification
Code
Sanitary
Ex-proof
Applicable Model
General
AE***DH
AE***MH
AE***DN
AE14
AE***DG
AE***MG AE14
AE***MN
Waterproof glands are attached to all wiring ports.
For JIS G1/2 only.
Waterproof glands (union joint) are attached to all
wiring ports. For JIS G1/2 only.
Gaskets are attached between earth ring and flow
tube. (Not available with 65, 125mm)
Eliminating DC Noise (Size 15mm(0.5in.) or larger:
Conductivity 50
S/cm or higher.)
Built-in Lightning Protector(Only for 24VDC version)
Digital Communication with BRAIN protocol
Digital Communication with HART protocol
Digital Communication with FOUNDATION Fieldbus
protocol (except 24 VDC version)
PID control function and Link Master function
Coating is changed to epoxy coating.
Coating is changed to three-layer coating(Urethane
coating on two-layer Epoxy coating)
Reproduced material certificate for pipe, electrode,
earth ring, mini-flange and flange (depends on
spec.).
Carbon steel bolts/nuts and chloroprene gaskets
assembly for wafer type
Carbon steel bolts/nuts and non-asbestos PTFE-
wrapped gaskets assembly for wafer type
wStainless steel bolts/nuts and chloroprene gaskets
assembly for wafer type
Stainless steel bolts/nuts and non-asbestos PTFE-
wrapped gaskets assembly for wafer type
Condensation proof for District Heating and Cooling
use. Terminal box; urethane resin potting. Wired 30m
signal cable at factory.
FM Explosion proof/FM Nonincendive
CENELEC ATEX Explosion proof
CSA Explosion proof/CSA Nonincendive
SAA Explosion proof
JIS Flameproof type
One Flameproof Packing Adapter and a blind plug
are attached.(only for DC power supply)
Two Flameproof Packing Adapters are attached.(Not
apply for one port wiring.)
Calibration Certificate for GOST (only for products
produced at YMF)
In case of fluid temp. over 120
°
C (248
°
F), 160
°
C
(320
°
F) max. (Not available with 65mm)
Mirror Finishing on the inside of ceramic tube
(Rmax.<=1 micro-meter)
180deg. rotated converter for reversed flow direction
Degreased cleansing treatment
Degreased cleansing treatment; Packing with
desiccant
Test pressure depends on process connection
(Test duration 10 minutes) Test result is full in NOTE
of QIC.
Level 2:Declaration and Calibration Equipment List
Level 3:Declaration and Primary Standard List
Level 4:Declaration and YOKOGAWA Measuring
Waterproof Gland
Waterproof Gland with Union
Joint
Gaskets for PVC pipe
DC Noise Suppression
Lightning Protector
BRAIN Communication(Note 1)
HART Communication(Note 1)
FOUNDATION Fieldbus
Communication (Note 1)
PID/LM function for
FOUNDATION Fieldbus (Note 6)
Epoxy Coating
High Anti-corrosion Coating
Material Certificate(Note 2)
Bolt & Nut Assembly(Note 3 )
DHC use (for size 100 to 400mm)
FM Approval(Note 4)
CENELEC ATEX Certification
(KEMA Approval)
CSA Certification(Note 4)
SAA Certification
JIS Flameproof
(Note 4)(Note 5)
Flameproof Packing Adapter
for JIS Flameproof (Note 5)
(Only for JIS G1/2 electrical
connection)
GOST Certification
Silicon Rubber Gasket for
sanitary type
Mirror Finished Ceramics
180deg. Rotated Converter
Oil-prohibited Use
Oil-prohibited Use with
Dehydrating Treatment
Hydrostatics Test Certificate
Calibration Certificate
T19.EPS
Note 1:
Either BRAIN, HART, or FOUNDATION Fieldbus communication can be selected.
Note 2:
In case of requirement of EN10204 3.1B for Material Certificate, contact Yokogawa office.
Note 3:
It is available only for JIS 10K wafer, JIS 20K wafer or ANSI 150 wafer type, not available with 65, 125, 250 or 300mm.
Note 4:
It is available only for size 2.5 to 200mm(0.1 to 8 in).
Note 5:
Select optional code /JF3 with /G11 or /G12 in case of requirement of JIS Flameproof type.
/G11 is selectable only for DC power supply and 4-conductor cable use.
Note 6:
Optional code /LC1 is a function for Fieldbus communication. Optional code /FB must be selected together with /LC1.
Note 7:
Ex-proof Fieldbus communication is available for CENELEC ATEX and FM ex-proof version.
: Available –: Not available
AE***SC
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
(Note 5)
(Note 5)
(Note 5)
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
/ECG
/ECU
/FRG
/ELC
/A
/BR
/HART
/FB
/LC1
/EPF
/X2
/M01
/BCC
/BCF
/BSC
/BSF
/DHC
/FF1/FN1
/KF2
/CF1/CN1
/SF1
/JF3
/G11
/G12
/GOS
/SRG
/MRR
/CRC
/K1
/K5
/T01
/L2
/L3
/L4
Note 7
Note 7
Note 7