7. OPERATION VIA BRAIN TERMINAL
IM 1E7B0-02E
7-15
7.2.20 Other Important Points to Note
(1) The automatic power-off function turns the terminal off automatically if no key is
pressed for about 5 minutes or more. However, this function does not operate when
the terminal is displaying the variables in (2) below.
(2) When A10 FLOW RATE (%) or A20 FLOW RATE is displayed, data are updated
every 5 seconds.
(3) UPLD is used when the parameters of one ADMAG AE are copied to the BT and
DNLD is used when the parameters copied to the BT are copied to another ADMAG
AE. (For details, see the "BT200 Instruction Manual " (IM 1C0A11-01E).
Parameters that can be copied include span and pulse factor parameters such as the
following:
B02 DAMPING, B03 FLOW SPAN, B04 FLOW UNIT, B05 TIME UNIT
B06 SIZE UNIT, B07 NOMINAL SIZE, B10 OUTPUT FUNC, B11 4-20 ALM OUT
D01 DISP SELECT, D02 FL USER SEL, D03 FL USER SPAN, D10 FL
USERUNIT, E01 TOTAL UNIT, E02 TOTAL SCALE, E03 TOTAL LOWCUT,
E04 TOTAL SET, E05 TL SET VALUE, E10 TL USER UNIT, F01 PULSE
SELECT, F02 PULSE SCALE, F03 PULSE LOW CUT, F04 PULSE WIDTH,
G01 4-20 LOW CUT, G02 4-20 LOW LMT, G03 4-20 H LMT.