![YOKOGAWA AE100D Скачать руководство пользователя страница 137](http://html.mh-extra.com/html/yokogawa/ae100d/ae100d_instruction-manual_911083137.webp)
IM 1E7B0-02E
13-1
13. PRESSURE EQUIPMENT DIRECTIVE
13. PRESSURE EQUIPMENT DIRECTIVE
This chapter is described further requirements and
notices concerning the PED (Pressure Equipment
Directive). The description in this chapter is prior to
other description in this User's Manual.
(1) Technical Data
Module : H
Type of Equipment : Piping
Type of Fluid : Liquid and Gas
Group of Fluid : 1 and 2
General Purpose / Explosion Proof
MODEL
AE102MG/MN/SC
AE105MG/MN/SC
AE110MG/MN/SC
AE115MG/MN/SC
AE202MG/MN/SC
AE204MG/MN/SC
AE205MG/MN/SC
AE206MG/MN/SC
AE208MG/MN/SC
AE210MG/MN/SC
AE212MG/MN/SC
AE215MG/MN/SC
AE220MG/MN/SC
AE325MG/MN/SC
AE330MG/MN/SC
AE335MG/MN/SC
AE340MG/MN/SC
DN
(mm)*
2.5
5
10
15
25
40
50
65
80
100
125
150
200
250
300
350
400
PS
(MPa)*
4
4
4
4
4
4
4
2
2
2
2
2
2
2
2
2
2
PS·DN
(MPa·mm)
10
20
40
60
100
160
200
130
160
200
250
300
400
500
600
700
800
CATEGORY**
Article 3,
paragraph 3
Article 3,
paragraph 3
Article 3,
paragraph 3
Article 3,
paragraph 3
Article 3,
paragraph 3
II
II
II
II
II
II
II
III
III
III
III
III
***
***
***
***
***
T1301.EPS
Sanitary
MODEL
AE202MH
AE204MH
AE205MH
AE206MH
AE208MH
AE210MH
DN
(mm)*
25
40
50
65
80
100
PS
(MPa)*
1
1
1
1
1
1
PS·DN
(MPa·mm)
25
40
50
65
80
100
CATEGORY**
Article 3,
paragraph 3
I
I
I
I
I
***
T01302.EPS
*
PS: Maximum allowable pressure for Flow Tube
DN: Nominal size
** Referred to Table 6 covered by ANNEX II of EC
Directive on Pressure Equipment Directive 97/23/
EC)
*** AE102MG/MN/SC to AE202MG/MN/SC, and
AE202MH are not attached CE mark of PED
because they do not come under CE marking of
PED.
(2) Installation
WARNING
• Please tighten the bolts for piping-joint accord-
ing to the prescribed torque values.
• Please take measure to protect the flowmeters
from forces caused by vibration through piping.
(3) Operation
WARNING
• The temperature and pressure of fluid should
be applied under the normal operating condi-
tion.
• The ambient temperature should be applied
under the normal operating condition.
• Please pay attention to prevent the excessive
pressure like water hammer, etc. When water
hammer is to be occurred, please take
measures to prevent the pressure from
exceeding PS(maximum allowable pressure) by
setting the safety valve, etc. at the system and
the like.
• When external fire is to be occurred, please
take safety measures at the device or system
not to influence the flowmeters.
• Please avoid the fluid exceeding the corrosion
proof of lining and electrode.