IM 1F6A0-01E
2-9
2. GENERAL DESCRIPTION
Item
Specification
Code
Applicable Model
T020403-2.EPS
Pilling up coating to keep off corrosion
Epoxy and Polyurethane coating for the purpose of corrosion - proof
improvement; salt damage, alkali, climate and acidity
Each certificate to be attached produced by the vendors
Meterbody
1. Meterbody, 2. Shedder bar
1. Meterbody, 2. Shedder bar, 3. Bottom plug
1. Meterbody, 2. Shedder bar, 3. Bottom plug, 4. Welding rod
Each certificate to be attached produced by the vendors
Meterbody
1. Meterbody, 2. Shedder bar
1. Meterbody, 2. Shedder bar, 3. Bottom plug
1. Meterbody, 2. Shedder bar, 3. Bottom plug, 4. Welding rod
Each certificate to be attached
Meterbody
1. Meterbody, 2. Shedder bar
Each certificate to be attached
The customer’s name and job name to be specified when ordered.
1. Welded portion for the bottom plug
2. Welded portion for the flange in case of the welding
construction
Each certificate to be attached
1. Welded portion for the bottom plug
2. Welded portion for the flange in case of the welding
construction
Material certificates: Mill sheets
Material certificates: 3.1B
3.1B certificate to be attached
according to EN10204
PAMI test certificate
Positive Material Identification
certificate to be attached for the main 3
chemical components of specified
materials
WQ, WPS, PQR
The welding documents to be attached
such as Welder's Qualification,
Welding Procedure Specification, and
Procedure Qualification Record.
Dye Penetrant test certificate
Dye Penetrant test certificate for the
welded portion to be attached
Item to be
specified
Item to be
specified
Item to be
specified
Item to be
specified
Item to be
specified
M01
M02
M03
M04
E01
E02
E03
E04
PM1
PM2
WP
PT
X2
DY
DY
DY250, DY300
DY, DYA
DY
DY
DY
(Note 1) When /SCT is not chosen, the specified Tag Number is engraved on the data plate.
When /SCT is chosen, the specified Tag Number is engraved on the data plate and stainless tag plate.
(Note 2) There is a case that calibration water should stay in the meter tube. So this is not degrease treatment in the strict sense.
(Note 3) The output is set 3.6mA or less (General type is set 21.6mA or more at shipping).
(Note 4) Now preparing.
(Note 5) When /CRC is choosen, the electrical connection turn to a down stream side.
(Note 6) Refer to P2-9: “OPTION MULTI-VARIABLE (BUILD IN TEMPERATURE SENSOR) TYPE (/MV)”